Failure of suture material at suture anchor eyelets

被引:64
作者
Meyer, DC [1 ]
Nyffeler, RW [1 ]
Fucentese, SF [1 ]
Gerber, C [1 ]
机构
[1] Univ Zurich, Dept Orthopaed, CH-8008 Zurich, Switzerland
关键词
suture anchor; eyelet; failure load; suture material; anchor orientation;
D O I
10.1053/jars.2002.36115
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: In the repair of soft tissue to bone using suture anchors, failure of the suture material can occur at the anchor eyelet. This study examines the load strength at which suture material fails with different metallic suture anchor eyelets. Type of study: Biomechanical study. Methods: Suture material (Ethibond No. 2, Ethicon, Norderstedt, Germany) was pulled out from 22 metallic suture anchor models at 60 mm/min, and tensile load at failure and failure mode were recorded. Tests were performed either by simultaneous pulling on 2 suture limbs in 3 different directions (straight, at 450, and at 45degrees rotated by 90degrees to the suture anchor axis) or by pulling on 1 suture limb while measuring the resulting force on the second limb. All tests were performed until suture failure. Pulling was performed in single tests on an Instron materials testing machine (High Wycombe, UK), with the anchors held by a vise. Results: In all cases, the suture failed at the anchor eyelet. Failure load at straight loading ranged from 116 +/- 5 N to 226 +/- 5 N and from 69 5 N to 193 7 N when loaded at an angle of 45degrees. The best results were found with the Statak 5.2-mm (Zimmer, Warsaw, IN): 177 N; Corkscrew 6.5-mm anchor (Arthrex, Naples, FL): 174 N; and PeBA 4.0-mm anchor (OBL Orthopaedic Biosystems, Scottsdale, AZ): 169 N. With each eyelet, sutures failed preferentially in 1 direction, depending on the presence of sharp edges. Conclusions: Suture material can be cut at suture anchor eyelets. Failure load depends on sharp edges on the eyelet and occurs at forces up to 73% below the breaking strength of the suture material on a smooth hook. Anchors with suture-protecting channels are particularly sensitive to the orientation in which the sutures are loaded.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 15 条
[1]
Suture anchors - Update 1999 [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 1999, 15 (07) :719-725
[2]
Internal fixation strength of suture anchors - Update 1997 [J].
Barber, FA ;
Herbert, MA ;
Click, JN .
ARTHROSCOPY, 1997, 13 (03) :355-362
[3]
THE ULTIMATE STRENGTH OF SUTURE ANCHORS [J].
BARBER, FA ;
HERBERT, MA ;
CLICK, JN .
ARTHROSCOPY, 1995, 11 (01) :21-28
[4]
Suture anchor strength revisited [J].
Barber, FA ;
Herbert, MA ;
Click, JN .
ARTHROSCOPY, 1996, 12 (01) :32-38
[5]
Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation [J].
Burkhart, SS ;
Pagan, JLD ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (06) :720-724
[6]
PULL-OUT STRENGTH OF 5 SUTURE ANCHORS [J].
CARPENTER, JE ;
FISH, DN ;
HUSTON, LJ ;
GOLDSTEIN, SA .
ARTHROSCOPY, 1993, 9 (01) :109-113
[7]
Craft D V, 1996, J Shoulder Elbow Surg, V5, P32, DOI 10.1016/S1058-2746(96)80028-0
[8]
Experimental rotator cuff repair - A preliminary study [J].
Gerber, C ;
Schneeberger, AG ;
Perren, SM ;
Nyffeler, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1281-1290
[9]
MECHANICAL STRENGTH OF REPAIRS OF THE ROTATOR CUFF [J].
GERBER, C ;
SCHNEEBERGER, AG ;
BECK, M ;
SCHLEGEL, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :371-380
[10]
GERBER C, 1996, ORTHOPAEDIC SPORTS M, P140