Suture anchor strength revisited

被引:71
作者
Barber, FA
Herbert, MA
Click, JN
机构
[1] PLANO ORTHOPED & SPORTS MED CTR,PLANO,TX
[2] MED CITY DALLAS HOSP,ADV SURG INST,DALLAS,TX
来源
ARTHROSCOPY | 1996年 / 12卷 / 01期
关键词
suture anchor; Mitek; miniHarpoon; PeBA; ROC; miniMitek; Fastak; ultimate load;
D O I
10.1016/S0749-8063(96)90216-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The rapid proliferation of suture anchors continues. Our prior report on the pullout strength of 14 different anchors is supplemented by a similar test conducted on 8 additional anchors. Comparative data on modes of failure and failure strengths (ultimate loads to failure) for these new devices are compared statistically with the previously tested anchors. In a fresh never-frozen porcine femur model, 10 samples of each of the additional anchors tested were threaded with stainless steel sutures and inserted into three different test areas (diaphyseal cortex, metaphyseal cortex, and a cancellous trough). Tensile stress parallel to the axis of insertion was applied at a rate of 12.5 mm/s by an Instron 1321 testing machine (Instron Corp, Canton, MA) until failure and mean anchor failure strengths calculated. The anchors tested were the Mitek G2 as a control, miniMitek, Mitek Superanchor, Mitek Rotator Cuff anchor (Mitek Products, Westwood, MA), Innovasive Devices Radial Osteal Compression device (Innovasive Devices, Hopkinton, MA), Arthrex Fastak (Arthrex Inc, Naples, FL), Arthrotek miniHarpoon (Arthrotek, Warsaw, IN), Orthopedic Biosystems PeBA 3 and PeBA 5 (Orthopedic Biosystems, Scottsdale, AZ), and AME 5.5 screw (American Medical Electronics, Richardson, TX). Failure mode (anchor pullout, suture eyelet cut out, or wire breakage) was generally consistent for each anchor type. The size of insertion hole is clinically important and each anchor's performance was evaluated as a function of its minor diameter or drill hole. For screw anchors, the larger the minor diameter of the screw, the higher the mean failure strengths in all three test areas (P = .001). However, larger drill holes for non-screw anchors resulted in lower mean failure strengths in cancellous bone (P = .03) and diaphyseal cortex (P < .005).
引用
收藏
页码:32 / 38
页数:7
相关论文
共 23 条
[1]   SUTURE ANCHOR FAILURE STRENGTH - AN IN-VIVO STUDY [J].
BARBER, FA ;
CAWLEY, P ;
PRUDICH, JF .
ARTHROSCOPY, 1993, 9 (06) :647-652
[2]   REPAIR OF AVULSED INSERTION OF BICEPS - A NEW TECHNIQUE IN 4 CASES [J].
BARNES, SJ ;
COLEMAN, SG ;
GILPIN, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (06) :938-939
[3]  
BARTLETT EC, 1993, APR ARTHR ASS N AM A
[4]  
BOVARD RS, 1994, ORTHOP REV, P167
[5]   PULL-OUT STRENGTH OF 5 SUTURE ANCHORS [J].
CARPENTER, JE ;
FISH, DN ;
HUSTON, LJ ;
GOLDSTEIN, SA .
ARTHROSCOPY, 1993, 9 (01) :109-113
[6]  
CHEN D S, 1992, Journal of Foot Surgery, V31, P134
[7]  
Edwards D J, 1994, J Shoulder Elbow Surg, V3, P230, DOI 10.1016/S1058-2746(09)80040-2
[8]  
GILLQUIST J, 1992, OPER TECH ORTHOP, V2, P104
[9]   THE MITEK-MINI-GII ANCHOR INTRODUCED FOR TENDON REINSERTION IN THE HAND [J].
HALLOCK, GG .
ANNALS OF PLASTIC SURGERY, 1994, 33 (02) :211-213
[10]   PULL-OUT STRENGTH OF SUTURE ANCHORS FOR ROTATOR CUFF AND BANKART LESION REPAIRS [J].
HECKER, AT ;
SHEA, M ;
HAYHURST, JO ;
MYERS, ER ;
MEEKS, LW ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :874-879