Characterisation of bone following ultrasonic cutting

被引:23
作者
Claire, Sunil [1 ]
Lea, Simon C. [1 ]
Walmsley, A. Damien [1 ]
机构
[1] Univ Birmingham, Sch Dent, Birmingham B4 6NN, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
Ultrasonic surgery; Vibration; Performance; Bone cutting;
D O I
10.1007/s00784-012-0754-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Ultrasonic surgery is an increasingly popular technique for cutting bone, but little research has investigated how the ultrasonic tip oscillations may affect the cuts they produce in bone. The aim of this investigation was to evaluate the oscillation and cutting characteristics of an ultrasonic surgical device. A Piezosurgery 3 (Mectron, Carasco, Italy) ultrasonic cutting system was utilised with an OP3 style tip. The system was operated with the tip in contact with porcine bone samples (loads of 50 to 200 g) mounted at 45A degrees to the vertical insert tip and with a water flow of 57 ml/min. Tip oscillation amplitude was determined using scanning laser vibrometry. Bone surfaces defects were characterised using laser profilometry and scanning electron microscopy. A positive relationship was observed between the magnitude of tip oscillations and the dimensions of defects cut into the bone surface. Overloading the tip led to a reduction in oscillation and hence in the defect produced. A contact load of 150 g provided the greatest depth of cut. Defects produced in the bone came from two clear phases of cutting. The structure of the bone was found to be an important factor in the cut characteristics following piezosurgery. Cutting of bone with ultrasonics is influenced by the load applied and the setting used. Care must be used to prevent the tip from sliding over the bone at low loadings.
引用
收藏
页码:905 / 912
页数:8
相关论文
共 14 条
[1]   Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone [J].
Alam, K. ;
Mitrofanov, A. V. ;
Silberschmidt, V. V. .
MEDICAL ENGINEERING & PHYSICS, 2011, 33 (02) :234-239
[2]  
Arnez J, 2009, ACTA CHIR PLAST, V53, P207
[3]   Enhancing Oral Implantology With Power Ultrasonics [J].
Cardoni, Andrea .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (09) :1936-1942
[4]   Cavitation occurrence around ultrasonic dental scalers [J].
Felver, Bernhard ;
King, David C. ;
Lea, Simon C. ;
Price, Gareth J. ;
Walmsey, A. Damien .
ULTRASONICS SONOCHEMISTRY, 2009, 16 (05) :692-697
[5]   CLINICAL-APPLICATIONS OF ULTRASONIC INSTRUMENTATION IN THE SURGICAL REMOVAL OF BONE [J].
HORTON, JE ;
TARPLEY, TM ;
JACOWAY, JR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 51 (03) :236-242
[6]   Investigations into the use of an ultrasonic chisel to cut bone. Part 1: forces applied by clinicians [J].
Khambay, BS ;
Walmsley, AD .
JOURNAL OF DENTISTRY, 2000, 28 (01) :31-37
[7]   Assessing the vibrations of dental ultrasonic scalers [J].
Lea, SC ;
Landini, G ;
Walmsey, AD .
JOURNAL OF SOUND AND VIBRATION, 2004, 271 (3-5) :1113-1120
[8]   Mechano-physical and biophysical properties of power-driven scalers: driving the future of powered instrument design and evaluation [J].
Lea, Simon C. ;
Walmsley, A. Damien .
PERIODONTOLOGY 2000, 2009, 51 :63-78
[9]   A finite element model for ultrasonic cutting [J].
Lucas, Margaret ;
MacBeath, Alan ;
McCulloch, Euan ;
Cardoni, Andrea .
ULTRASONICS, 2006, 44 :E503-E509
[10]   Cutting characteristics of ultrasonic surgical instruments [J].
Parmar, Dipesh ;
Mann, Malveen ;
Walmsley, A. Damien ;
Lea, Simon C. .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (12) :1385-1390