Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter

被引:150
作者
Boersma, Lucas V. A. [1 ]
Wijffets, Maurits C. E. F. [1 ]
Oral, Hakan [2 ]
Wever, Eric F. D. [1 ]
Morady, Fred [2 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3430 EM Nieuwegein, Netherlands
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Arrhythmia; Atrial fibrillation; Catheter ablation; Pulmonary vein isolation;
D O I
10.1016/j.hrthm.2008.08.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Pulmonary vein (PV) isolation for ablation of atrial fibrillation (AF) remains a complex and lengthy procedure. OBJECTIVE The purpose of this study was to evaluate the feasibility and safety of a novel multielectrode catheter that delivers duty-cycled bipolar and unipolar radiofrequency (RF) energy. METHODS Patients eligible for catheter ablation of paroxysmal AF after screening with magnetic resonance imaging and transesophageal echocardiography were included in the study. A decapolar (3-mm electrode, 3-mm spacing, 25-mm diameter), circular, over-the-wire mapping and ablation catheter was deployed in the antrum of each PV. Ablation was performed with 60-second, 60 degrees C applications of duty-cycled bipolar/unipolar RF in a 4:1 ratio simultaneously at all selected electrode pairs until local activity was no longer observed. At 6 months, 7-day Holter monitoring was performed to determine freedom from AF without use of antiarrhythmic drugs. RESULTS In 98 patients (mean age 59 +/- 9 years), the PV ablation catheter was used for ablation of 369 veins (20 common left antra). All targeted veins (100%) were isolated as confirmed by the absence of potentials in the ostium either by PV ablation catheter or Lasso mapping. Mean number of RF applications was 27 +/- 7, total procedural time 84 +/- 29 minutes, and fluoroscopy time 18 +/- 8 minutes. Follow-up after 6 months without antiarrhythmic drugs showed freedom from AF in 83% of patients. No procedure-related complications were observed. CONCLUSION PV isolation by duty-cycled bipolar/unipolar low-power RF energy through a circular, decapolar catheter can be achieved safety and efficiently, with good efficacy at 6 months.
引用
收藏
页码:1635 / 1642
页数:8
相关论文
共 32 条
[1]  
BOERSMA LVA, 2008, HEART RHYTHM S, V5, pS19
[2]  
BOERSMA LVA, 2008, HEART RHYTHM S, V5, pS368
[3]   Lethal atrioesophageal fistula after pulmonary vein isolation using high-intensity focused ultrasound (HIFU) [J].
Borchert, Bianca ;
Lawrenz, Thorsten ;
Hansky, Bert ;
Stellbrink, Christoph .
HEART RHYTHM, 2008, 5 (01) :145-148
[4]   Comparison of bipolar and unipolar radiofrequency ablation in an in vivo experimental model [J].
Bugge, E ;
Nicholson, IA ;
Thomas, SP .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (01) :76-80
[5]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[6]   Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation [J].
Cappato, R ;
Calkins, H ;
Chen, SA ;
Davies, W ;
Iesaka, Y ;
Kalman, J ;
Kim, YH ;
Klein, G ;
Packer, D ;
Skanes, A .
CIRCULATION, 2005, 111 (09) :1100-1105
[7]   Long-term single procedure efficacy of catheter ablation of atrial fibrillation [J].
Cheema, Aamir ;
Vasamreddy, Chandrasekhar R. ;
Dalal, Darshan ;
Marine, Joseph E. ;
Dong, Jun ;
Henrikson, Charles A. ;
Spragg, David ;
Cheng, Alan ;
Nazarian, Saman ;
Sinha, Sunil ;
Halperin, Henry ;
Berger, Ronald ;
Calkins, Hugh .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (03) :145-155
[8]   Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation [J].
Cheema, Aamir ;
Dong, Jun ;
Dalal, Darshan ;
Vasamreddy, Chandrasekhar R. ;
Marine, Joseph E. ;
Henrikson, Charles A. ;
Spragg, David ;
Cheng, Alan ;
Nazarian, Saman ;
Sinha, Sunil ;
Halperin, Henry ;
Berger, Ronald ;
Calkins, Hugh .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (10) :1080-1085
[9]  
DANG L, 2008, EUROPACE S1, V10, pI184
[10]   Atrial fibrillation ablation: Reaching the mainstream [J].
Fisher, JD ;
Spinelli, MA ;
Mookherjee, D ;
Krumerman, AK ;
Palma, EC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (05) :523-537