Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter

被引:150
作者
Boersma, Lucas V. A. [1 ]
Wijffets, Maurits C. E. F. [1 ]
Oral, Hakan [2 ]
Wever, Eric F. D. [1 ]
Morady, Fred [2 ]
机构
[1] St Antonius Hosp, Dept Cardiol, NL-3430 EM Nieuwegein, Netherlands
[2] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
Arrhythmia; Atrial fibrillation; Catheter ablation; Pulmonary vein isolation;
D O I
10.1016/j.hrthm.2008.08.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Pulmonary vein (PV) isolation for ablation of atrial fibrillation (AF) remains a complex and lengthy procedure. OBJECTIVE The purpose of this study was to evaluate the feasibility and safety of a novel multielectrode catheter that delivers duty-cycled bipolar and unipolar radiofrequency (RF) energy. METHODS Patients eligible for catheter ablation of paroxysmal AF after screening with magnetic resonance imaging and transesophageal echocardiography were included in the study. A decapolar (3-mm electrode, 3-mm spacing, 25-mm diameter), circular, over-the-wire mapping and ablation catheter was deployed in the antrum of each PV. Ablation was performed with 60-second, 60 degrees C applications of duty-cycled bipolar/unipolar RF in a 4:1 ratio simultaneously at all selected electrode pairs until local activity was no longer observed. At 6 months, 7-day Holter monitoring was performed to determine freedom from AF without use of antiarrhythmic drugs. RESULTS In 98 patients (mean age 59 +/- 9 years), the PV ablation catheter was used for ablation of 369 veins (20 common left antra). All targeted veins (100%) were isolated as confirmed by the absence of potentials in the ostium either by PV ablation catheter or Lasso mapping. Mean number of RF applications was 27 +/- 7, total procedural time 84 +/- 29 minutes, and fluoroscopy time 18 +/- 8 minutes. Follow-up after 6 months without antiarrhythmic drugs showed freedom from AF in 83% of patients. No procedure-related complications were observed. CONCLUSION PV isolation by duty-cycled bipolar/unipolar low-power RF energy through a circular, decapolar catheter can be achieved safety and efficiently, with good efficacy at 6 months.
引用
收藏
页码:1635 / 1642
页数:8
相关论文
共 32 条
[11]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[12]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[13]   Techniques for curative treatment of atrial fibrillation [J].
Hocini, M ;
Sanders, P ;
Jaïs, P ;
Hsu, LF ;
Takahashi, Y ;
Rotter, M ;
Clémenty, J ;
Haïssaguerre, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (12) :1467-1471
[14]   Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation -: A randomized comparison between 2 current ablation strategies [J].
Karch, MR ;
Zrenner, B ;
Deisenhofer, I ;
Schreieck, JR ;
Ndrepepa, G ;
Dong, J ;
Lamprecht, K ;
Barthel, P ;
Luciani, E ;
Schömig, A ;
Schmitt, C .
CIRCULATION, 2005, 111 (22) :2875-2880
[15]   Long-term follow-up after radiofrequency catheter ablation for atrial fibrillation [J].
Katritsis, Demosthenes ;
Wood, Mark A. ;
Giazitzogiou, Eleftherios ;
Shepard, Richard K. ;
Kourlaba, Georgia ;
Ellenbogen, Kenneth A. .
EUROPACE, 2008, 10 (04) :419-424
[16]  
MICHAUD GF, 2008, HEART RHYTHM S, V5, pS313
[17]   A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate [J].
Nademanee, K ;
McKenzie, J ;
Kosar, E ;
Schwab, M ;
Sunsaneewitayakul, B ;
Vasavakul, T ;
Khunnawat, C ;
Ngarmukos, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) :2044-2053
[18]   COMPARISON OF IN-VIVO TISSUE TEMPERATURE PROFILE AND LESION GEOMETRY FOR RADIOFREQUENCY ABLATION WITH A SALINE-IRRIGATED ELECTRODE VERSUS TEMPERATURE CONTROL IN A CANINE THIGH MUSCLE PREPARATION [J].
NAKAGAWA, H ;
YAMANASHI, WS ;
PITHA, JV ;
ARRUDA, M ;
WANG, XZ ;
OHTOMO, K ;
BECKMAN, KJ ;
MCCLELLAND, JH ;
LAZZARA, R ;
JACKMAN, WM .
CIRCULATION, 1995, 91 (08) :2264-2273
[19]   Initial experience using a forward directed, high-intensity focused ultrasound balloon catheter for pulmonary vein antrum isolation in patients with atrial fibrillation [J].
Nakagawa, Hiroshi ;
Antz, Matthias ;
Wong, Tom ;
Schmidt, Boris ;
Ernst, Sabine ;
Ouyang, Feifan ;
Vogtmann, Thomas ;
Wu, Richard ;
Yokoyama, Katsuaki ;
Lockwood, Deborah ;
Po, Sunny S. ;
Beckman, Karen J. ;
Davies, D. Wyn ;
Kuck, Karl-Heinz ;
Jackman, Warren M. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (02) :136-144
[20]   First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation [J].
Natale, A ;
Pisano, E ;
Shewchik, J ;
Bash, D ;
Fanelli, R ;
Potenza, D ;
Santarelli, P ;
Schweikert, R ;
White, R ;
Saliba, W ;
Kanagaratnam, L ;
Tchou, P ;
Lesh, M .
CIRCULATION, 2000, 102 (16) :1879-1882