Considerations on the possibilities and limitations of comprehensive normal phase-reversed phase liquid chromatography (NPLC x RPLC)

被引:56
作者
François, I
de Villiers, A
Sandra, P
机构
[1] Univ Ghent, Dept Organ Chem, Ghent, Belgium
[2] Univ Ghent, Pfizer Analyt Res Ctr, Ghent, Belgium
关键词
citrus oil extracts; comprehensive LC; normal phase LC; peak capacity; pharmaceuticals; Reversed phase LC;
D O I
10.1002/jssc.200500451
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comprehensive normal phase system LC-reversed phase LC (NPLC X RPLC) was evaluated for the separation of a pharmaceutical Mixture and citrus oil extracts. NPLC was performed on a 25 cm x 1 mm ID x 5 mu m d(p) diol phase. In the second dimension, an RP 18 monolithic column (10 cm L x 4.6 mm ID x 2 mu m macropore size) and an octadecyl silicagel-packed column (5 cm L x 4.6 mm ID x 3.5 mu m d(p)) were applied for the analyses of the pharmaceutical sample and the citrus oil extracts. respectively. A two-position/ten-port switching valve was used as interface. Under optimised LC conditions, the high degree of orthogonality between NP and RP resulted in peak capacities of 300 for the pharmaceutical sample and of 450 for the citrus oil extract composed of lemon and orange oil. Despite the features of NPLC x RPLC, several shortcomings related with the solvent incompatibility between the two LC modes were identified and the practical consequences were discussed.
引用
收藏
页码:492 / 498
页数:7
相关论文
共 29 条
[1]   Analysis of antioxidant compounds in sweet orange peel by HPLC-diode array detection-electrospray ionization mass spectrometry [J].
Anagnostopoulou, MA ;
Kefalas, P ;
Kokkalou, E ;
Assimopoulou, AN ;
Papageorgiou, VP .
BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (02) :138-148
[2]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[3]   LC-MS for the identification of oxygen heterocyclic compounds in citrus essential oils [J].
Dugo, P ;
Mondello, L ;
Dugo, L ;
Stancanelli, R ;
Dugo, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 24 (01) :147-154
[4]   Comprehensive two-dimensional normal-phase (adsorption) - Reversed-phase liquid chromatography [J].
Dugo, P ;
Favoino, O ;
Luppino, R ;
Dugo, G ;
Mondello, L .
ANALYTICAL CHEMISTRY, 2004, 76 (09) :2525-2530
[5]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[6]   Quantification of total furocournarins in citrus oils by HPLC coupled with UV, fluorescence, and mass detection [J].
Frérot, E ;
Decorzant, E .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (23) :6879-6886
[8]   SAMPLE DIMENSIONALITY - A PREDICTOR OF ORDER-DISORDER IN COMPONENT PEAK DISTRIBUTION IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :3-15
[9]   TWO-DIMENSIONAL SEPARATIONS - CONCEPT AND PROMISE [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :1258-&
[10]  
GIDDINGS JC, 1990, MULTIDIMENSIONAL CHR, P1