We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements.
引用
收藏
页码:243 / 245
页数:3
相关论文
共 19 条
[1]
RADIATION EXPOSURE OF PERSONNEL DURING DIGITAL SUBTRACTION ANGIOGRAPHY [J].
BRITTON, CA ;
WHOLEY, MH .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) :108-110
[2]
Percutaneous vertebroplasty with polymethylmethacrylate - Technique, indications, and results [J].
Deramond, H ;
Depriester, C ;
Galibert, P ;
Le Gars, D .
RADIOLOGIC CLINICS OF NORTH AMERICA, 1998, 36 (03) :533-+
[3]
Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures [J].
Fletcher, DW ;
Miller, DL ;
Balter, S ;
Taylor, MA .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (04) :391-397
[4]
Patient radiation exposure during coronary angiography and intervention [J].
Fransson, SG ;
Persliden, J .
ACTA RADIOLOGICA, 2000, 41 (02) :142-144
[5]
Monitoring of trauma surgeons' exposure to radiation.: Measurements of hand, eye and thyroid with highly sensitive thermoluminescence detectors [J].
Fuchs, M ;
Modler, H ;
Schmid, A ;
Dumont, C ;
Stürmer, KM .
UNFALLCHIRURG, 1999, 102 (05) :371-376
[6]
Long-term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplasty [J].
Grados, F ;
Depriester, C ;
Cayrolle, G ;
Hardy, N ;
Deramond, H ;
Fardellone, P .
RHEUMATOLOGY, 2000, 39 (12) :1410-1414
[7]
Dose reduction in evacuation proctography [J].
Hare, C ;
Halligan, S ;
Bartram, CI ;
Gupta, R ;
Walker, AE ;
Renfrew, I .
EUROPEAN RADIOLOGY, 2001, 11 (03) :432-434
[8]
Ishiguchi Tsuneo, 2000, Nippon Acta Radiologica, V60, P839
[9]
A review of image quality and dose issues in digital fluorography and digital subtraction angiography [J].
Kotre, CJ ;
Marshall, NW .
RADIATION PROTECTION DOSIMETRY, 2001, 94 (1-2) :73-76
[10]
Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding [J].
Kuon, E ;
Schmitt, M ;
Dahm, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01) :44-49