Estimation of coronary flow reserve using the thrombolysis in myocardial infarction (TIMI) frame count method

被引:98
作者
Manginas, A [1 ]
Gatzov, P [1 ]
Chasikidis, C [1 ]
Voudris, V [1 ]
Pavlides, G [1 ]
Cokkinos, DV [1 ]
机构
[1] Onassis Cardiac Surg Ctr, Dept Cardiol, Athens 17674, Greece
关键词
D O I
10.1016/S0002-9149(99)00149-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A simple and readily available method of estimating coronary flow velocity reserve may have significant clinical value. With use of intracoronary adenosine we documented a very good correlation between coronary flow reserve values obtained with the Thrombolysis In Myocardial Infaction trial frame count method and the invasive Doppler wire (Flowire) technique.
引用
收藏
页码:1562 / +
页数:5
相关论文
共 20 条
[1]   Current concepts of coronary flow reserve for clinical decision making during cardiac catheterisation [J].
Baumgart, D ;
Haude, M ;
Liu, FQ ;
Ge, JB ;
Goerge, G ;
Erbel, R .
AMERICAN HEART JOURNAL, 1998, 136 (01) :136-149
[2]   ABNORMAL CARDIAC PAIN PERCEPTION IN SYNDROME-X [J].
CHAUHAN, A ;
MULLINS, PA ;
THURAISINGHAM, SI ;
TAYLOR, G ;
PETCH, MC ;
SCHOFIELD, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :329-335
[3]   Impact of injection rate on the Thrombolysis In Myocardial Infarction (TIMI) trial frame count [J].
Dodge, JT ;
Rizzo, M ;
Nykiel, M ;
Altmann, J ;
Hobkirk, K ;
Brennan, M ;
Gibson, CM .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (10) :1268-+
[4]   Abnormal coronary flow in infarct arteries 1 year after myocardial infarction is predicted at 4 weeks by corrected thrombolysis in myocardial infarction (TIMI) frame count and stenosis severity [J].
French, JK ;
Ellis, CJ ;
Webber, BJ ;
Williams, BF ;
Amos, DJ ;
Ramanathan, K ;
Whitlock, RML ;
White, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (06) :665-671
[5]   Comparison of intracoronary Doppler guide wire and transesophageal echocardiography in measurement of flow velocity and coronary flow reserve in the left anterior descending coronary artery [J].
Gadallah, S ;
Thaker, KB ;
Kawanishi, D ;
Mehra, A ;
Lau, S ;
Rashtian, M ;
Chandraratna, PAN .
AMERICAN HEART JOURNAL, 1998, 135 (01) :38-42
[6]   Rescue angioplasty in the thrombolysis in myocardial infarction (TIMI) 4 trial [J].
Gibson, CM ;
Cannon, CP ;
Greene, RM ;
Sequeira, RF ;
Margorien, RD ;
Leya, F ;
Diver, DJ ;
Baim, DS ;
Braunwald, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (01) :21-26
[7]   TIMI frame count: A quantitative method of assessing coronary artery flow [J].
Gibson, CM ;
Cannon, CP ;
Daley, WL ;
Dodge, JT ;
Alexander, B ;
Marble, SJ ;
McCabe, CH ;
Raymond, L ;
Fortin, T ;
Poole, WK ;
Braunwald, E .
CIRCULATION, 1996, 93 (05) :879-888
[8]  
Gibson M., 1997, Journal of the American College of Cardiology, V29, p201A
[9]  
Hartley C J, 1989, Int J Card Imaging, V4, P159, DOI 10.1007/BF01745146
[10]   Determination of angiographic (TIMI grade) blood flow by intracoronary Doppler flow velocity during acute myocardial infarction [J].
Kern, MJ ;
Moore, JA ;
Aguirre, FV ;
Bach, RG ;
Caracciolo, EA ;
Wolford, T ;
Khoury, AF ;
Mechem, C ;
Donohue, TJ .
CIRCULATION, 1996, 94 (07) :1545-1552