Comparison of intracoronary Doppler guide wire and transesophageal echocardiography in measurement of flow velocity and coronary flow reserve in the left anterior descending coronary artery

被引:31
作者
Gadallah, S [1 ]
Thaker, KB [1 ]
Kawanishi, D [1 ]
Mehra, A [1 ]
Lau, S [1 ]
Rashtian, M [1 ]
Chandraratna, PAN [1 ]
机构
[1] Univ So Calif, Div Cardiol, Sch Med, USC Med Ctr,LAC, Los Angeles, CA 90033 USA
关键词
D O I
10.1016/S0002-8703(98)70340-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The intracoronary Doppler tipped guide wire has been shown to be highly accurate in the measurement of coronary flow velocity (CFV). Recent studies have indicated that blood flow velocity in the left anterior descending coronary artery (LAD) con be determined by transesophageal echocardiography (TEE). The purpose of this study was to compare Row velocity recordings and coronary Flow reserve measurements in the IAD by TEE with those obtained by Doppler guide wire. Methods and Results The study population consisted of 14 patients with chest pain and normal coronary arteriograms. After routine coronary arteriography was performed, a 0.014-inch Doppler guide wire was advanced into the proximal part of the LAD. After baseline measurement of coronary flow velocity (CFV) was obtained, 140 mu g/kg/min adenosine was administered intravenously for 3 minutes, and the flow velocity was recorded. TEE was performed within 24 hours of the cardiac catheterization. After baseline measurements of CFV in the IAD, heart rate, and blood pressure were obtained, 140 mu g/kg/min adenosine was administered intravenously, and the CFV was recorded. Coronary flow reserve was calculated as the ratio of the peak diastolic CFV during adenosine infusion to the peak diastolic CFV at baseline. A good correlation was found (r = 0.91, p < 0.0001) between CFV by Doppler guide wire and that determined by TEE. A good correlation was also found between the coronary flow reserve assessed by Doppler guide wire and that determined by TEE (r = 0.92, p < 0.0001). Conclusion Our data indicate that CFV and coronary flow reserve in the IAD can be accurately measured by transesophageal echocardiography.
引用
收藏
页码:38 / 42
页数:5
相关论文
共 12 条
[1]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[2]  
HUTCHISON S, 1993, CIRCULATION S, V1, P67
[3]  
HUTCHISON S, 1994, AM J CARDIOL, V15, P1063
[4]  
HUTCHISON S, 1997, ECHOCARDIOGR-J CARD, V12, P591
[5]   TRANSESOPHAGEAL DOPPLER ECHOCARDIOGRAPHY EVALUATION OF CORONARY BLOOD-FLOW VELOCITY IN BASE-LINE CONDITIONS AND DURING DIPYRIDAMOLE-INDUCED CORONARY VASODILATION [J].
ILICETO, S ;
MARANGELLI, V ;
MEMMOLA, C ;
RIZZON, P .
CIRCULATION, 1991, 83 (01) :61-69
[6]   ASSESSMENT OF ANGIOGRAPHICALLY INTERMEDIATE CORONARY-ARTERY STENOSIS USING THE DOPPLER FLOWIRE [J].
KERN, MJ ;
DONOHUE, TJ ;
AGUIRRE, FV ;
BACH, RG ;
CARACCIOLO, EA ;
OFILI, E ;
LABOVITZ, AJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (14) :D26-D33
[7]   IMPAIRED CORONARY VASODILATOR RESERVE IN THE IMMEDIATE POSTCORONARY ANGIOPLASTY PERIOD - ANALYSIS OF CORONARY-ARTERY FLOW VELOCITY INDEXES AND REGIONAL CARDIAC VENOUS EFFLUX [J].
KERN, MJ ;
DELIGONUL, U ;
VANDORMAEL, M ;
LABOVITZ, A ;
GUDIPATI, CV ;
GABLIANI, G ;
BODET, J ;
SHAH, Y ;
KENNEDY, HL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (04) :860-872
[8]  
THAKER K, 1994, CIRCULATION S, V1, P61
[9]  
WHILE CW, 1993, AM J CARDIOL, V71, pD10
[10]   TRANS-LUMINAL, SUBSELECTIVE MEASUREMENT OF CORONARY-ARTERY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN MAN [J].
WILSON, RF ;
LAUGHLIN, DE ;
ACKELL, PH ;
CHILIAN, WM ;
HOLIDA, MD ;
HARTLEY, CJ ;
ARMSTRONG, ML ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1985, 72 (01) :82-92