Comparison of Droplet Digital PCR and Seminested Real-Time PCR for Quantification of Cell-Associated HIV-1 RNA

被引:123
作者
Kiselinova, Maja [1 ,2 ]
Pasternak, Alexander O. [3 ]
De Spiegelaere, Ward [1 ,2 ]
Vogelaers, Dirk [1 ,2 ]
Berkhout, Ben [3 ]
Vandekerckhove, Linos [1 ,2 ]
机构
[1] Univ Ghent, Dept Internal Med, HIV Translat Res Unit HTRU, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Ghent, Belgium
[3] Univ Amsterdam, Acad Med Ctr, Ctr Infect & Immun Amsterdam CINIMA, Dept Med Microbiol,Lab Expt Virol, NL-1105 AZ Amsterdam, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 01期
基金
比利时弗兰德研究基金会;
关键词
GENE-EXPRESSION ANALYSIS; LOW-LEVEL VIREMIA; DNA COPY NUMBER; ANTIRETROVIRAL THERAPY; ABSOLUTE QUANTITATION; PLASMA VIREMIA; VIRUS; REPLICATION; LOAD;
D O I
10.1371/journal.pone.0085999
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cell-associated (CA) HIV-1 RNA is considered a potential marker for assessment of viral reservoir dynamics and antiretroviral therapy (ART) response in HIV-infected patients. Recent studies employed sensitive seminested real-time quantitative (q)PCR to quantify CA HIV-1 RNA. Digital PCR has been recently described as an alternative PCR-based technique for absolute quantification with higher accuracy compared to qPCR. Here, a comparison was made between the droplet digital PCR (ddPCR) and the seminested qPCR for quantification of unspliced (us) and multiply spliced (ms) CA HIV-1 RNA. Synthetic RNA standards and CA HIV-1 RNA from infected patients on and off ART (N = 34) were quantified with both methods. Correlations were observed between the methods both for serially diluted synthetic standards (usRNA: R-2 = 0.97, msRNA: R-2 = 0.92) and patient-derived samples (usRNA: R-2 = 0.51, msRNA: R-2 = 0.87). Seminested qPCR showed better quantitative linearity, accuracy and sensitivity in the quantification of synthetic standards than ddPCR, especially in the lower quantification ranges. Both methods demonstrated equally high detection rate of usRNA in patient samples on and off ART (91%), whereas ddPCR detected msRNA in larger proportion of samples from ART-treated patients (p = 0.13). We observed an average agreement between the methods for usRNA quantification in patient samples, albeit with a large standard deviation (bias = 0.05 +/- 0.75 log(10)). However, a bias of 0.94 +/- 0.36 log(10) was observed for msRNA. No-template controls were consistently negative in the seminested qPCR, but yielded a positive ddPCR signal for some wells. Therefore, the false positive signals may have affected the detection power of ddPCR in this study. Digital PCR is promising for HIV nucleic acid quantification, but the false positive signals need further attention. Quantitative assays for CA HIV RNA have the potential to improve monitoring of patients on ART and to be used in clinical studies aimed at HIV eradication, but should be cross-validated by multiple laboratories prior to wider use.
引用
收藏
页数:8
相关论文
共 31 条
[11]   Single-Nucleotide Polymorphisms and Other Mismatches Reduce Performance of Quantitative PCR Assays [J].
Lefever, Steve ;
Pattyn, Filip ;
Hellemans, Jan ;
Vandesompele, Jo .
CLINICAL CHEMISTRY, 2013, 59 (10) :1470-1480
[12]   HIV cure and eradication: how will we get from the laboratory to effective clinical trials? [J].
Lewin, Sharon R. ;
Rouzioux, Christine .
AIDS, 2011, 25 (07) :885-897
[13]   Use of real-time PCR and molecular beacons to detect virus replication in human immunodeficiency virus type 1 infected individuals on prolonged effective antiretroviral therapy [J].
Lewin, SR ;
Vesanen, M ;
Kostrikis, L ;
Hurley, A ;
Duran, M ;
Zhang, L ;
Ho, DD ;
Markowitz, M .
JOURNAL OF VIROLOGY, 1999, 73 (07) :6099-6103
[14]   Characterization of LEDGF/p75 Genetic Variants and Association with HIV-1 Disease Progression [J].
Messiaen, Peter ;
De Spiegelaere, Ward ;
Alcami, Jose ;
Vervisch, Karen ;
Van Acker, Petra ;
Verhasselt, Bruno ;
Meuwissen, Pieter ;
Calonge, Esther ;
Gonzalez, Nuria ;
Gutierrez-Rodero, Felix ;
Rodriguez-Martin, Carmen ;
Sermijn, Erica ;
Poppe, Bruce ;
Vogelaers, Dirk ;
Verhofstede, Chris ;
Vandekerckhove, Linos .
PLOS ONE, 2012, 7 (11)
[15]   Low-level viremia persists for at least 7 years in patients on suppressive antiretroviral therapy [J].
Palmer, Sarah ;
Malclarelli, Frank ;
Wiegand, Ann ;
Bernstein, Barry ;
Hanna, George J. ;
Brun, Scott C. ;
Kempf, Dale J. ;
Mellors, John W. ;
Coffin, John M. ;
King, Martin S. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (10) :3879-3884
[16]   Highly sensitive methods based on seminested real-time reverse transcription-PCR for quantitation of human immunodeficiency virus type 1 unspliced and multiply spliced RNA and proviral DNA [J].
Pasternak, Alexander O. ;
Adema, Karen W. ;
Bakker, Margreet ;
Jurriaans, Suzanne ;
Berkhout, Ben ;
Cornelissen, Marion ;
Lukashov, Vladimir V. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (07) :2206-2211
[17]   Cell-associated HIV RNA: a dynamic biomarker of viral persistence [J].
Pasternak, Alexander O. ;
Lukashov, Vladimir V. ;
Berkhout, Ben .
RETROVIROLOGY, 2013, 10
[18]   Modest Nonadherence to Antiretroviral Therapy Promotes Residual HIV-1 Replication in the Absence of Virological Rebound in Plasma [J].
Pasternak, Alexander O. ;
de Bruin, Marijn ;
Jurriaans, Suzanne ;
Bakker, Margreet ;
Berkhout, Ben ;
Prins, Jan M. ;
Lukashov, Vladimir V. .
JOURNAL OF INFECTIOUS DISEASES, 2012, 206 (09) :1443-1452
[19]   Steady increase in cellular HIV-1 load during the asymptomatic phase of untreated infection despite stable plasma viremia [J].
Pasternak, Alexander O. ;
Jurriaans, Suzanne ;
Bakker, Margreet ;
Berkhout, Ben ;
Lukashov, Vladimir V. .
AIDS, 2010, 24 (11) :1641-1649
[20]   Cellular Levels of HIV Unspliced RNA from Patients on Combination Antiretroviral Therapy with Undetectable Plasma Viremia Predict the Therapy Outcome [J].
Pasternak, Alexander O. ;
Jurriaans, Suzanne ;
Bakker, Margreet ;
Prins, Jan M. ;
Berkhout, Ben ;
Lukashov, Vladimir V. .
PLOS ONE, 2009, 4 (12)