Optimization of thermoelectric heat pumps by operating condition management and heat exchanger design

被引:60
作者
David, Benjamin [1 ]
Ramousse, Julien [1 ]
Luo, Lingai [1 ]
机构
[1] Univ Savoie, CNRS, LOCIE, UMR 5271, F-73376 Le Bourget Du Lac, France
关键词
Thermoelectric hear pump; Heat exchangers; Optimization; Analytical model; COP maximization; Entropy generation minimization; PERFORMANCE; COOLER;
D O I
10.1016/j.enconman.2012.02.007
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
This paper introduces an optimization method for improving thermoelectric heat pump performance by operating condition management of the thermoelectric modules (TEMs) and design optimization of the heat exchangers linked to the TEMs. The device studied, corresponding to an original configuration of the thermoelectric heat pump, comprises two commercial thermoelectric modules and two mini-channel heat sinks through which water flows, in contact with both sides of the TEMs. The objective function is the maximization of the device's coefficient of performance (COP), including the electrical and mechanical consumption of the thermoelectric modules and the circulating auxiliaries. First, the optimization variables are the number and the diameter of mini-channels, and the mass flows for both heat sinks (hot and cold sides). The results show that similar results are obtained by minimization of the entropy generation in the device. Finally, the hot thermal power demand is included in the optimization variables for complete optimization of the device. The results of full optimization converge with those obtained with the previous partial optimization, (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:125 / 133
页数:9
相关论文
共 33 条
[2]
Method of entropy generation minimization, or modeling and optimization based on combined heat transfer and thermodynamics [J].
Bejan, A .
REVUE GENERALE DE THERMIQUE, 1996, 35 (418-19) :637-646
[3]
Performances of thermoelectric cooler integrated with microchannel heat sinks [J].
Chein, RY ;
Chen, YH .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06) :828-839
[4]
Heat transfer effect on the specific cooling load of refrigerators [J].
Chen, LG ;
Wu, C ;
Sun, FR .
APPLIED THERMAL ENGINEERING, 1996, 16 (12) :989-997
[5]
Optimization of cross flow heat exchangers for thermoelectric waste heat recovery [J].
Crane, DT ;
Jackson, GS .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) :1565-1582
[6]
David B, 2010, OPTIMIZATION THERMOE, P25
[7]
DM Rowes, 1995, CRC HDB THERMOELECTR
[8]
FERROTEC, 2012, FERR MAN COMP MAT SY
[9]
DESIGN CONSIDERATIONS FOR A THERMOELECTRIC REFRIGERATOR [J].
GOKTUN, S .
ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (12) :1197-1200
[10]
Khan WA, 2006, OPTIMIZATION MICROCH