Enzyme shadowing:: using antibody-enzyme dually-labeled magnetic particles for fast bacterial detection

被引:16
作者
Baldrich, Eva [1 ]
Xavier Munoz, Francesc [1 ]
机构
[1] Esfera UAB, IMB CNM, CSIC, Barcelona 08193, Spain
关键词
D O I
10.1039/b805536j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using magnetic particles and immunoseparation for target recovery and detection has been reported to improve the performance and detection limits of traditional analytical methods. For example, magnetic immunocapture can be coupled to detection in a sandwich format using an antibody (Ab) labeled with a reporter molecule or enzyme. In this work we demonstrate that simultaneous incorporation of capture and reporter biocomponents onto the sensing surface is possible and provides assays that are extremely fast and easy to carry out. As a proof of concept, we have produced dually-labeled magnetic particles, simultaneously functionalized with antibody and reporter enzyme. Subsequent capture of Escherichia coli generates a shadowing effect on the particle surface and interferes with the activity of a number of enzyme units. The decrease in signal recorded is proportional to the bacterial concentration and is specific for the target microorganism, with a detection limit of 10(3)-10(4) cell mL(-1) in an assay of about one hour.
引用
收藏
页码:1009 / 1012
页数:4
相关论文
共 12 条
  • [1] Bruno JG, 1996, J MOL RECOGNIT, V9, P474, DOI 10.1002/(SICI)1099-1352(199634/12)9:5/6<474::AID-JMR286>3.0.CO
  • [2] 2-0
  • [3] Automated immunomagnetic separation and microarray detection of E-coli O157:H7 from poultry carcass rinse
    Chandler, DP
    Brown, J
    Call, DR
    Wunschel, S
    Grate, JW
    Holman, DA
    Olson, L
    Stottlemyre, MS
    Bruckner-Lea, CJ
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 70 (1-2) : 143 - 154
  • [4] Enzyme-linked immunomagnetic chemiluminescence incorporating anti-H7 and anti-O157 antibodies for the detection of Escherichia coli O157:H7
    Gehring, Andrew G.
    Irwin, Peter L.
    Reed, Sue A.
    Tu, Shu-I
    [J]. JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2006, 14 (04) : 349 - 361
  • [5] Fluorescent detection of cyanobacterial DNA using bacterial magnetic particles on a MAG-microarray
    Matsunaga, T
    Nakayama, H
    Okochi, M
    Takeyama, H
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2001, 73 (05) : 400 - 405
  • [6] An immunomagnetic separator for concentration of pathogenic micro-organisms from large volume samples
    Rotariu, O
    Ogden, ID
    MacRae, M
    Badescu, V
    Strachan, NJC
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2005, 293 (01) : 589 - 596
  • [7] Automated methods for multiplexed pathogen detection
    Straub, TM
    Dockendorff, BP
    Quiñonez-Díaz, MD
    Valdez, CO
    Shutthanandan, JI
    Tarasevich, BJ
    Grate, JW
    Bruckner-Lea, CJ
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 62 (03) : 303 - 316
  • [8] Rapid detection of outbreak Escherichia coli O157 and Salmonella on alfalfa sprouts by immunomagnetic capture and time-resolved fluorescence
    Tu, SI
    Golden, M
    Fett, WF
    Gehring, A
    Irwin, P
    [J]. JOURNAL OF FOOD SAFETY, 2003, 23 (02) : 75 - 89
  • [9] Detection of immunomagnetically captured Escherichia coli O157:H7 by antibody-conjugated alkaline phosphatase
    Tu, SI
    Patterson, D
    Briggs, C
    Irwin, P
    Yu, L
    [J]. JOURNAL OF INDUSTRIAL MICROBIOLOGY & BIOTECHNOLOGY, 2001, 26 (06) : 345 - 349
  • [10] Yazdankhah SP, 1998, VET MICROBIOL, V62, P17, DOI 10.1016/S0378-1135(98)00193-X