PIV applied to Eckart streaming produced by a medical ultrasound transducer

被引:21
作者
Cosgrove, JA [1 ]
Buick, JM
Pye, SD
Greated, CA
机构
[1] Univ Edinburgh, Dept Phys & Astron, Fluids & Acoust Grp, Edinburgh EH9 3JZ, Midlothian, Scotland
[2] Univ Edinburgh, Dept Med Phys, Edinburgh EH9 3JZ, Midlothian, Scotland
关键词
acoustic streaming; particle image velocimetry; medical ultrasound transducer;
D O I
10.1016/S0041-624X(01)00072-5
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Particle image velocimetry (PIV) is applied for the first time to study Eckart streaming induced by a medical ultrasonic transducer operating at a frequency of 3.3 MHz and effective acoustic intensities of 0.25 and 3 W cm(-2), A temporal series of velocities in a two-dimensional plane were recorded resulting in an experimental set comprising over half a million velocity data points. These enabled average and fluctuating properties to be determined and clearly indicated the quasi-steady nature of the flow. The average large scale velocity fluctuations along the axis caused by this quasi-steady property were calculated to be 2 and 20 in ms(-1) at effective intensities of 0.25 and 3 W cm(-2) respectively corresponding to approximately 25% of the peak flow velocity in both cases. Furthermore averaged shear rates were calculated with peak values of 1 and 8 s(-1) for the low and high intensities respectively. The present investigation indicates the usefulness of PIV for such studies and serves as a prelude to investigations of streaming in biological type fluids. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:461 / 464
页数:4
相关论文
共 13 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]   Review of LDA and PIV applied to the measurement of sound and acoustic streaming [J].
Campbell, M ;
Cosgrove, JA ;
Greated, CA ;
Jack, S ;
Rockliff, D .
OPTICS AND LASER TECHNOLOGY, 2000, 32 (7-8) :629-639
[3]  
COSGROVE JA, 2001, P 8 INT C SOUND VIBR
[4]   VISCOSITY MEASUREMENT OF AN ENCLOSED LIQUID USING ULTRASOUND [J].
HERTZ, TG ;
DYMLING, SO ;
LINDSTROM, K ;
PERSSON, HW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (02) :457-462
[5]   EFFECTS OF NONLINEARITY IN DEVELOPMENT OF ACOUSTIC STREAMING [J].
MITOME, H ;
KOZUKA, T ;
TUZIUTI, T .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1995, 34 (5B) :2584-2589
[6]  
Mitome H, 1998, ELECTRON COMM JPN 3, V81, P1, DOI 10.1002/(SICI)1520-6440(199810)81:10<1::AID-ECJC1>3.0.CO
[7]  
2-9
[8]   On the measurement of strain rate in an oscillatory baffled column using particle image velocimetry [J].
Ni, X ;
Cosgrove, JA ;
Arnott, AD ;
Greated, CA ;
Cumming, RH .
CHEMICAL ENGINEERING SCIENCE, 2000, 55 (16) :3195-3208
[9]   THE PERFORMANCE OF ULTRASOUND PHYSIOTHERAPY MACHINES IN LOTHIAN REGION, SCOTLAND, 1992 [J].
PYE, SD ;
MILFORD, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (04) :347-359
[10]  
SARRITT HC, 1989, ULTRASOUND MED BIOL, V14, P363