Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images

被引:21
作者
Khurshid, Khawar [1 ]
McGough, Robert J. [1 ]
Berger, Kevin [2 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Radiol, E Lansing, MI 48824 USA
关键词
D O I
10.1088/0031-9155/53/20/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Error-free reconstruction of PET data with a registered CT attenuation map is essential for accurate quantification and interpretation of cardiac perfusion. Misalignment of the CT and PET data can produce an erroneous attenuation map that projects lung attenuation parameters onto the heart wall, thereby underestimating the attenuation and creating artifactual areas of hypoperfusion that can be misinterpreted as myocardial ischemia or infarction. The major causes of misregistration between CT and PET images are the respiratory motion, cardiac motion and gross physical motion of the patient. The misalignment artifact problem is overcome with automated cardiac registration software that minimizes the alignment error between the two modalities. Results show that the automated registration process works equally well for any respiratory phase in which the CT scan is acquired. Further evaluation of this procedure on 50 patients demonstrates that the automated registration software consistently aligns the two modalities, eliminating artifactual hypoperfusion in reconstructed PET images due to PET/CT misregistration. With this registration software, only one CT scan is required for PET/CT imaging, which reduces the radiation dose required for CT-based attenuation correction and improves the clinical workflow for PET/CT.
引用
收藏
页码:5705 / 5718
页数:14
相关论文
共 14 条
[1]  
Beyer T, 2000, J NUCL MED, V41, P1369
[2]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[4]   Frequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: A definitive analysis of causes, consequences, and corrections [J].
Gould, K. Lance ;
Pan, Tinsu ;
Loghin, Catalin ;
Johnson, Nils P. ;
Guha, Ashrith ;
Sdringola, Stefano .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (07) :1112-1121
[5]  
HARVEY D, 2004, RADIOLOGY TODAY, V5, P13
[6]   RECENT CONVERGENCE RESULTS FOR THE FUZZY C-MEANS CLUSTERING ALGORITHMS [J].
HATHAWAY, RJ ;
BEZDEK, JC .
JOURNAL OF CLASSIFICATION, 1988, 5 (02) :237-247
[7]   Induction of fuzzy rules and membership functions from training examples [J].
Hong, TP ;
Lee, CY .
FUZZY SETS AND SYSTEMS, 1996, 84 (01) :33-47
[8]  
Koepfli P, 2004, J NUCL MED, V45, P537
[9]   Clinical experience with the first combined positron emission tomography/computed tomography scanner in Australia [J].
Lau, WFE ;
Binns, DS ;
Ware, RE ;
Ramdave, S ;
Cachin, F ;
Pitman, AG ;
Hicks, RJ .
MEDICAL JOURNAL OF AUSTRALIA, 2005, 182 (04) :172-+
[10]  
MOLLER A, 2007, J NUCL MED, V48, P188