Intraosseous Ultrasound in the Placement of Pedicle Screws in the Lumbar Spine

被引:57
作者
Kantelhardt, Sven R. [1 ]
Bock, Christoph H. [1 ]
Larsen, Joerg [2 ]
Bockermann, Volker [1 ]
Schillinger, Wolfgang [3 ]
Rohde, Veit [1 ]
Giese, Alf [1 ]
机构
[1] Univ Gottingen, Dept Neurosurg, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Neuroradiol, D-37075 Gottingen, Germany
[3] Univ Gottingen, Dept Cardiol & Pulmonol, D-37075 Gottingen, Germany
关键词
pedicle screw placement; ultrasonography; bone sonography; lumbar spine fixation; lumbar spine; MINIATURE ROBOTIC GUIDANCE; FUSION; ACCURACY; COMPLICATIONS; SURGERY; NAVIGATION; INSERTION; SYSTEM; TIME;
D O I
10.1097/BRS.0b013e31819286ca
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Study Design. Experimental and intraoperative evaluation of the efficiency of a novel technique. Objective. To determine the accuracy of pedicle screw hole placements before screw implantation in the lumbar spine. Summary of Background Data. Deviations from planned trajectories occur in a significant number of screw placements in posterior lumbar fixation. Several techniques have been proposed to minimize this complication, although none has gained general acceptance. This may be due to costs associated with their implementation or considerably extended operating times required by some techniques. Methods. Pedicle screw holes were placed in 24 pedicles of 2 postmortem human lumbar spine specimens. Sixteen optimal trajectories were placed and 8 intentional cortical breaches. Each pedicular drill hole was examined using a 360 ultrasound transducer and CT scanning. The ultrasonographic images were reviewed by 3 independent investigators who were blinded to the CT findings. In addition, 20 screw holes were placed intraoperatively in 3 patients, and equally assessed by intraoperative intraosseous ultrasonography and postoperative CT scanning. Results. Ultrasonographic images of pedicle screw holes in postmortem human spine specimen were correctly interpreted in 99% of cases. No cortical breech was missed, i.e., no false-negatives occurred. Intraoperative findings closely matched the experimental data. None of the intraoperative ultrasound scans demonstrated a cortical breach, a finding confirmed by postoperative CT. The intraoperative time required for the ultrasonographic analysis of each pedicle was about 1 minute and the interpretation of the resulting images was judged intuitive by the evaluating neurosurgeons. Conclusion. Intraosseous ultrasound is a highly reliable technique for the intraoperative assessment of pedicle screw holes before pedicle screw placement. Additional expenses with respect to procedure time and manpower are minimal.
引用
收藏
页码:400 / 407
页数:8
相关论文
共 24 条
[1]
Transpedicular screw placement -: Image-guided versus lateral-view fluoroscopy:: In vitro simulation [J].
Assaker, R ;
Reyns, N ;
Vinchon, M ;
Demondion, X ;
Louis, E .
SPINE, 2001, 26 (19) :2160-2164
[2]
Image-guided spine surgery - A cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models [J].
Austin, MS ;
Vaccaro, AR ;
Brislin, B ;
Nachwalter, R ;
Hilibrand, AS ;
Albert, TJ .
SPINE, 2002, 27 (22) :2503-2508
[3]
Miniature robotic guidance for spine surgery - introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres [J].
Barzilay, Y. ;
Liebergall, M. ;
Fridlander, A. ;
Knoller, N. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2006, 2 (02) :146-153
[4]
Reproducibility of serial intravascular ultrasound measurements in patients with angiographically silent coronary artery disease after heart transplantation [J].
Bocksch, W ;
Wellnhofer, E ;
Schartl, M ;
Dreysse, S ;
Klimek, W ;
Franke, R ;
Musci, M ;
Hetzer, R ;
Fleck, E .
CORONARY ARTERY DISEASE, 2000, 11 (07) :555-562
[5]
Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[6]
Complications in posterior fusion and instrumentation for degenerative lumbar scoliosis [J].
Cho, Kyu-Jung ;
Suk, Se-Il ;
Park, Seung-Rim ;
Kim, Jin-Hyok ;
Kim, Sung-Soo ;
Choi, Won-Kee ;
Lee, Kang-Yoon ;
Lee, Seung-Ryol .
SPINE, 2007, 32 (20) :2232-2237
[7]
Cook S D, 2001, Spine J, V1, P109, DOI 10.1016/S1529-9430(01)00020-1
[8]
COMPLICATIONS OF LUMBAR SPINAL-FUSION WITH TRANSPEDICULAR INSTRUMENTATION [J].
DAVNE, SH ;
MYERS, DL .
SPINE, 1992, 17 (06) :S184-S189
[9]
Early complications of spinal pedicle screw [J].
Faraj A.A. ;
Webb J.K. .
European Spine Journal, 1997, 6 (5) :324-326
[10]
Guigui P, 2004, REV CHIR ORTHOP, V90, P5