Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish

被引:61
作者
Endo, Hideaki [1 ]
Yonemori, Yuki [1 ]
Hibi, Kyoko [1 ]
Ren, Huifeng [1 ]
Hayashi, Tetsuhito [1 ]
Tsugawa, Wakako [2 ]
Sode, Koji [2 ]
机构
[1] Tokyo Univ Marine Sci & Technol, Dept Ocean Sci, Fac Marine Sci, Minato Ku, Tokyo 1088477, Japan
[2] Tokyo Univ Agr & Technol, Dept Biotechnol & Life Sci, Fac Engn, Koganei, Tokyo 1848588, Japan
关键词
Biosensor; Enzyme sensor; Glucose; Blood; Wireless; Telemetory; Real-time; Monitoring; Fish; RAINBOW-TROUT; CHOLESTEROL OXIDASE; ELECTRODE; PLASMA; STRESS; BIOCHEMISTRY; MICROSENSOR; RESISTANCE; BIOSENSOR; CORTISOL;
D O I
10.1016/j.bios.2008.08.038
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Periodic checks of fish health and the rapid detection of abnormalities are thus necessary at fish farms. Several studies indicate that blood glucose levels closely correlate to stress levels in fish and represent the state of respiratory or nutritional disturbance. We prepared a wireless enzyme sensor system to determine blood glucose levels in fish. it can be rapidly and conveniently monitored using the newly developed needle-type enzyme sensor, consisting of a Pt-Ir wire, Ag/AgCl paste, and glucose oxidase. To prevent the effects of interfering anionic species, such as uric acid and ascorbic acid, on the sensor response, the Pt-Ir electrode was coated with Nafion, and then glucose oxidase was immobilized on the coated electrode. The calibration curve of the glucose concentration was linear, from 0.18 to 144 mg/dl, and the detection limit was 0.18 mg/dl. The sensor was used to wirelessly monitor fish glucose levels. The sensor-calibrated glucose levels and actual blood glucose levels were in excellent agreement. The fluid of the inner sclera of the fish eyeball (EISF) was a suitable site for sensor implantation to obtain glucose sample. There was a close correlation between glucose concentrations in the EISF and those in the blood. Glucose concentrations in fish blood could be monitored in free-swimming fish in an aquarium for 3 days. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1417 / 1423
页数:7
相关论文
共 30 条
[1]   ENZYME ELECTRODE WITH COLLAGEN-IMMOBILIZED CHOLESTEROL OXIDASE FOR THE MICRO-DETERMINATION OF FREE-CHOLESTEROL [J].
BERTRAND, C ;
COULET, PR ;
GAUTHERON, DC .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1979, 12 (14) :1477-1488
[2]   An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[3]   First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system [J].
Caduff, A ;
Hirt, E ;
Feldman, Y ;
Ali, Z ;
Heinemann, L .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :209-217
[4]   A survey of potential stressor-induced physiological changes in carp (Cyprinus carpio) and barbel (Barbus bocagei) along the Tajo River [J].
Carballo, M ;
Jiménez, JA ;
de la Torre, A ;
Roset, J ;
Muñoz, MJ .
ENVIRONMENTAL TOXICOLOGY, 2005, 20 (02) :119-125
[5]   Physiological effects of dietary cadmium acclimation and waterborne cadmium challenge in rainbow trout: respiratory, ionoregulatory, and stress parameters [J].
Chowdhury, MJ ;
Pane, EF ;
Wood, CM .
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY C-TOXICOLOGY & PHARMACOLOGY, 2004, 139 (1-3) :163-173
[6]   Enzyme sensor system for determination of total cholesterol in fish plasma [J].
Endo, H ;
Maita, M ;
Takikawa, M ;
Ren, HF ;
Hayashi, T ;
Urano, N ;
Mitsubayashi, K .
FISHERIES SCIENCE, 2003, 69 (06) :1194-1199
[7]   A needle-type optical enzyme sensor system for determining glucose levels in fish blood [J].
Endo, Hideaki ;
Yonemori, Yuki ;
Musiya, Kazuya ;
Maita, Masashi ;
Shibuya, Toru ;
Ren, Huifeng ;
Hayashi, Tetsuhito ;
Mitsubayashi, Kohji .
ANALYTICA CHIMICA ACTA, 2006, 573 :117-124
[8]  
Gourzi M., 2003, Journal of Medical Engineering & Technology, V27, P276, DOI 10.1080/0309190031000098845
[9]  
Gourzi M., 2005, Journal of Medical Engineering & Technology, V29, P22, DOI 10.1080/03091900410001720247
[10]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007