X-ray response of epitaxial GaAs

被引:25
作者
Owens, A [1 ]
Bavdaz, M
Kraft, S
Peacock, A
Nenonen, S
Andersson, H
Gagliardi, MA
Gagliardi, T
Scholze, F
Ulm, G
机构
[1] European Space Agcy, ESTEC, Dept Space Sci, NL-2200 AG Noordwijk, Netherlands
[2] Metorex Int Oy, FIN-02201 Espoo, Finland
[3] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1063/1.370549
中图分类号
O59 [应用物理学];
学科分类号
摘要
We summarize the results of a number of x-ray experiments on an epitaxial GaAs device carried out in both our laboratory and the Physikalisch-Technishe Bundesanstalt radiometry Laboratory at the Berliner Elektronenspeicherring-Gesellschaft fur Synchrotronstrahlung Synchrotron Radiation Source. The detector has a diameter of 1.5 mm and is fully depleted to a depth of 40 mu m. It has been characterized as a function of energy, bias, and temperature. At -35 degrees C we determine the charge collection efficiency to be 97% and find that energy resolutions ranging from 730 to 930 eV full width at half maximum (FWHM) can be readily achieved using conventional pre-amplifiers over the energy range 6-60 keV. By considering the various contributions to the FWHM, we show that leakage current and charge trapping noise dominate the resolution function. From detector modeling we determine the effective electron and hole density/cross section products to be 7 and 3 cm(-1), respectively. (C) 1999 American Institute of Physics. [S0021-8979(99)06211-8].
引用
收藏
页码:7522 / 7527
页数:6
相关论文
共 15 条
[1]  
BAVDAZ M, 1998, MATER RES SOC S P, V487, P565
[2]   Energy resolution in GaAs X- and γ-ray detectors [J].
Bertuccio, G ;
Canali, C ;
Nava, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01) :29-35
[3]   Pixel X-ray detectors in epitaxial gallium arsenide with high-energy resolution capabilities (fano factor experimental determination) [J].
Bertuccio, G ;
Pullia, A ;
Lauter, J ;
Forster, A ;
Luth, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) :1-5
[4]   GaAs detectors - A review [J].
Buttar, CM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01) :1-8
[5]   Analysis of the active layer in SI GaAs Schottky diodes [J].
Castaldini, A ;
Cavallini, A ;
Polenta, L ;
Canali, C ;
Nava, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01) :79-84
[6]   EVALUATION OF EPITAXIAL N-GAAS FOR NUCLEAR RADIATION DETECTION [J].
EBERHARDT, JE ;
RYAN, RD ;
TAVENDALE, AJ .
NUCLEAR INSTRUMENTS & METHODS, 1971, 94 (03) :463-+
[7]   IONIZATION YIELD OF RADIATIONS .2. THE FLUCTUATIONS OF THE NUMBER OF IONS [J].
FANO, U .
PHYSICAL REVIEW, 1947, 72 (01) :26-29
[8]  
Feldhaus J., 1986, P SOC PHOTO-OPT INS, V0733, P242
[9]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[10]  
MCGREGOR DS, 1995, SEMICONDUCT SEMIMET, V43, P393