Fluorescent competitive flow-through assay for chloramphenicol using molecularly imprinted polymers

被引:62
作者
Suárez-Rodríguez, JL [1 ]
Díaz-García, ME [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
molecular imprinting; molecular recognition; sensor; optosensing; chloramphenicol;
D O I
10.1016/S0956-5663(01)00243-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It is a fact that molecular imprinting techniques have reached tremendous importance in the research of new artificial recognition systems. These methods resemble the mechanism of natural recognition, generally based on non-covalent interactions, but improving their stability by means of a simple and inexpensive technique, Molecular imprinting polymers (MIPs) are easily obtained by copolymerisation of suitable functional monomers and crosslinkers in the presence of the print molecule. Removal of the template leaves a polymer that selectively recognises it. In this work, different imprinted polymers for chloramphenicol (CAP) obtained using different monomers and polymerisation conditions were tested in a HPLC system, in order to obtain a highly selective material for CAP. The optimised MIP was then used as recognition phase in a fluorescent competitive flow assay to determine chloramphenicol. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:955 / 961
页数:7
相关论文
共 24 条
[1]   Study of the nature of recognition in molecularly imprinted polymers, II [1] - Influence of monomer-template ratio and sample load on retention and selectivity [J].
Andersson, HS ;
Karlsson, JG ;
Piletsky, SA ;
Koch-Schmidt, AC ;
Mosbach, K ;
Nicholls, IA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 848 (1-2) :39-49
[2]   On-line solid-phase extraction of triazine herbicides using a molecularly imprinted polymer for selective sample enrichment [J].
Bjarnason, B ;
Chimuka, L ;
Ramström, O .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2152-2156
[3]   Molecularly imprinted sensor layers for the detection of polycyclic aromatic hydrocarbons in water [J].
Dickert, FL ;
Tortschanoff, M ;
Bulst, WE ;
Fischerauer, G .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4559-4563
[4]   MOLECULAR IMPRINTING USED FOR CHIRAL SEPARATIONS [J].
KEMPE, M ;
MOSBACH, K .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) :3-13
[5]   COMPETITIVE AMPEROMETRIC MORPHINE SENSOR-BASED ON AN AGAROSE IMMOBILIZED MOLECULARLY IMPRINTED POLYMER [J].
KRIZ, D ;
MOSBACH, K .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :71-75
[6]   INTRODUCING BIOMIMETIC SENSORS BASED ON MOLECULARLY IMPRINTED POLYMERS AS RECOGNITION ELEMENTS [J].
KRIZ, D ;
RAMSTROM, O ;
SVENSSON, A ;
MOSBACH, K .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2142-2144
[7]  
KRIZ D, 1997, ANAL CHEM, V69, P345
[8]   Imprinted polymer based sensor system for herbicides using differential-pulse voltammetry on screen printed electrodes [J].
Kröger, S ;
Turner, APF ;
Mosbach, K ;
Haupt, K .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3698-3702
[9]   Optical detection of chloramphenicol using molecularly imprinted polymers [J].
Levi, R ;
McNiven, S ;
Piletsky, SA ;
Cheong, SH ;
Yano, K ;
Karube, I .
ANALYTICAL CHEMISTRY, 1997, 69 (11) :2017-2021
[10]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE QUANTITATION OF POLYAMINES AS THEIR DANSYL DERIVATIVES - APPLICATION TO PLANT AND ANIMAL-TISSUES [J].
MARCE, M ;
BROWN, DS ;
CAPELL, T ;
FIGUERAS, X ;
TIBURCIO, AF .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (02) :329-335