Airborne fungi in child day care centers in Edirne City, Turkey

被引:41
作者
Aydogdu, Halide [2 ]
Asan, Ahmet [1 ]
机构
[1] Trakya Univ, Fac Arts & Sci, Dept Biol, TR-22030 Edirne, Turkey
[2] Trakya Univ, Arda Vocat Coll, TR-22030 Edirne, Turkey
关键词
Airborne fungi; Child day care centers; Meteorological parameters; Microfungi; Biomass;
D O I
10.1007/s10661-007-0130-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study was to determine the concentration, in terms of monthly and seasonal distribution and in relation to meteorological factors, of indoor and outdoor microfungi at selected sites in several child day care centers in the city of Edirne, Turkey. Samples were collected at one month intervals over a period of 12 months between January-December 2004, by exposing petri plates containing Peptone Dextrose Agar with Rose-Bengal and Streptomycin medium to the air for 10-15 min. A total of 2,071 microfungal colonies were counted on 192 petri plates. Thirty microfungal genera (Acremonium, Alternaria, Arthrinium, Aspergillus, Bahusakala, Beauveria, Ceuthospora, Chaetomium, Cladosporium, Curvularia, Drechslera, Epicoccum, Eurotium, Fusarium, Mycotypha, Myrotechium, Paecilomyces, Penicillium, Pestalotiopsis, Phoma, Ramichloridium, Rhizopus, Scopulariopsis, Stachybotrys, Stemphylium, Torula, Trichoderma, Trichothecium, Ulocladium, Verticillium) and 75 microfungal species were isolated from the air indoor and outdoor of the day care centers. The dominant microfungal genera were Cladosporium, Penicillium and Alternaria (44.11%, 18.94%, 14.67% of the total respectively), while the genus with the most species richness was Penicillium (26 species). Alternaria, Cladosporium, Penicillium and non-sporulating microfungi were found every month. Cladosporium was the dominant genus in both indoor and outdoor air. Although the predominant genus was the same in both indoor and outdoor air, Cladosporium was followed by Penicillium, Alternaria and Aspergillus genera in indoor air and by Alternaria, Penicillium and Aspergillus genera in outdoor air. While a positive correlation was found between the concentration of monthly outdoor microfungi and monthly average temperature, a negative correlation was found between the concentration of monthly outdoor microfungi and monthly average wind velocity. Also, some relationships were found between the monthly concentrations of the most predominant microfungal genera (Cladosporium, Penicillium and Alternaria) and various meteorological factors.
引用
收藏
页码:423 / 444
页数:22
相关论文
共 70 条
[2]   Air-borne viable, non-viable, and allergenic fungi in a rural agricultural area of India: a 2-year study at five outdoor sampling stations [J].
Adhikari, A ;
Sen, MM ;
Gupta-Bhattacharya, S ;
Chanda, S .
SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 326 (1-3) :123-141
[3]   Natural exposure to Alternaria spores induces allergic rhinitis symptoms in sensitized children [J].
Andersson, M ;
Downs, S ;
Mitakakis, T ;
Leuppi, J ;
Marks, G .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2003, 14 (02) :100-105
[4]  
Asan A, 2002, BIOLOGIA, V57, P59
[5]   Monitoring of fungi and bacteria in the indoor air of primary schools in Edirne city, Turkey [J].
Aydogdu, H ;
Asan, A ;
Otkun, MT ;
Ture, M .
INDOOR AND BUILT ENVIRONMENT, 2005, 14 (05) :411-425
[6]  
BARNETT HL, 1999, ILLUSTRATED GENERA I, P21
[7]   Evaluation and a predictive model of airborne fungal concentrations in school classrooms [J].
Bartlett, KH ;
Kennedy, SM ;
Brauer, M ;
Van Netten, C ;
Dill, B .
ANNALS OF OCCUPATIONAL HYGIENE, 2004, 48 (06) :547-554
[8]   Influence of environmental factors on airborne fungi in houses of Santa Fe city, Argentina [J].
Basilico, Maria de la Luz Z. ;
Chiericatti, Carolina ;
Aringoli, E. Elena ;
Althaus, Rafael L. ;
Carlos Basilico, Juan .
SCIENCE OF THE TOTAL ENVIRONMENT, 2007, 376 (1-3) :143-150
[9]   Effects of meteorological conditions on spore plumes [J].
Burch, M ;
Levetin, E .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2002, 46 (03) :107-117
[10]   Indoor and outdoor mycoflora in the different districts of the city of Istanbul (Turkey) [J].
Çolakoglu, G .
INDOOR AND BUILT ENVIRONMENT, 2004, 13 (02) :91-100