Application of a rotating bioreactor consisting of low-cost and ready-to-use medical disposables for in vitro evaluation of the endothelialization efficiency of small-caliber vascular prostheses

被引:12
作者
Avci-Adali, Meltem [1 ]
Kobba, Joseph [1 ]
Neumann, Bernd [1 ]
Lescan, Mario [1 ]
Perle, Nadja [1 ]
Wilhelm, Nadja [1 ]
Wiedmaier, Hartmut [1 ]
Schlensak, Christian [1 ]
Wendel, Hans Peter [1 ]
机构
[1] Univ Tubingen Hosp, Dept Thorac Cardiac & Vasc Surg, D-72076 Tubingen, Germany
关键词
endothelialization; vascular prostheses; rotating bioreactor; hemocompatibility; endothelial cell seeding; CORONARY-ARTERIES; THROMBOTIC RISK; ELUTING STENTS; IMMOBILIZATION; DISEASE; DEVICES; GRAFTS;
D O I
10.1002/jbm.b.32916
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The incomplete endothelialization of especially small-caliber vascular prostheses after implantation in patients is a major disadvantage in cardiovascular interventions. The lack of an endothelium leads to the occurrence of thrombosis at the luminal surface of artificial vascular prostheses. Thus, the development of new graft materials and coatings for induction of complete endothelialization on the implant surfaces is a promising approach to improve hemocompatibility and maintain long-term graft patency. In this study, we designed a rotation model to evaluate the early endothelial cell (EC) seeding efficiency of different small-caliber vascular devices, such as stents and vascular grafts. The suitability of the designed rotation model for endothelialization studies was investigated by seeding and cultivation of prostheses with ECs followed by scanning electron microscopy. Furthermore, the viability of attached ECs was determined by calcein acetoxymethyl ester (AM) staining. The rotation model consisting of low-cost medical disposables enabled sterile incubation and cultivation of ECs with vascular devices. Simultaneously, the rotation of the bioreactor ensured a uniform distribution and adhesion of cells to the devices. Calcein AM staining of adherent cells on prostheses revealed excellent cell viability. Moreover, using the designed rotation model, an influence of different coatings and materials on the adhesion and spreading of ECs was demonstrated. The rotating bioreactor described and used in this study not only saves time and money but is also eminently useful for the accelerated preclinical evaluation of the endothelialization efficiency of different materials and surface coatings of small-caliber vascular devices. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
引用
收藏
页码:1061 / 1068
页数:8
相关论文
共 28 条
[1]
Clinical and angiographic outcome after coronary arterial stenting with the carbostent [J].
Antoniucci, D ;
Bartorelli, A ;
Valenti, R ;
Montorsi, P ;
Santoro, GM ;
Fabbiocchi, F ;
Bolognese, L ;
Loaldi, A ;
Trapani, M ;
Trabattoni, D ;
Moschi, G ;
Galli, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (07) :821-825
[2]
Improvements in GORE-TEX® Vascular Graft performance by Carmeda® BioActive Surface heparin immobilization [J].
Begovac, PC ;
Thomson, RC ;
Fisher, JL ;
Hughson, A ;
Gällhagen, A .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (05) :432-437
[3]
BURKEL WE, 1989, MED PROG TECHNOL, V14, P165
[4]
Death Toll From Uncontrolled Blood Pressure in Ethnic Populations: Universal Access and Quality Improvement May Not Be Enough [J].
Cene, Crystal Wiley ;
Cooper, Lisa A. .
ANNALS OF FAMILY MEDICINE, 2008, 6 (06) :486-489
[5]
Design of a novel rotating wall bioreactor for the in vitro simulation of the mechanical environment of the endothelial function [J].
Dermenoudis, Stergios ;
Missirlis, Yannis .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1426-1431
[6]
DeScheerder I, 1997, CIRCULATION, V95, P1549
[7]
A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[8]
Garner B, 1999, J BIOMED MATER RES, V44, P121, DOI 10.1002/(SICI)1097-4636(199902)44:2<121::AID-JBM1>3.0.CO
[9]
2-A
[10]
Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries [J].
Hardhammar, PA ;
vanBeusekom, HMM ;
Emanuelsson, HU ;
Hofma, SH ;
Albertsson, PA ;
Verdouw, PD ;
Boersma, E ;
Serruys, PW ;
vanderGiessen, WJ .
CIRCULATION, 1996, 93 (03) :423-430