Stereotactic biopsies guided by an optical navigation system:: Technique and clinical experience

被引:25
作者
Grunert, P [1 ]
Espinosa, J [1 ]
Busert, C [1 ]
Günthner, M [1 ]
Filippi, R [1 ]
Farag, S [1 ]
Hopf, N [1 ]
机构
[1] Univ Mainz, Abt Neurochirurg, Dept Neurosurg, D-55131 Mainz, Germany
关键词
stereotaxy; biopsy; intracranial tumors; frameless system;
D O I
10.1055/s-2002-23576
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Frame-based stereotactic biopsies are time-consuming procedures making necessary head fixation in a ring, explicit coordinate calculation and setting of the parameters. Frameless systems make many of these intermediate steps unnecessary, impose less mechanical restrictions regarding access to the lesions, and with slight modifications can be used to perform stereotactic biopsies. A special adaptation designed to fix the holder and the biopsy instrument is described. The neuronavigation optical tracking system of Radionics was used. CT scans were performed with 6 skin markers. Calibration was performed after head fixation in the Mayfield clamp. Mean calibration error was 2.19 +/- 0.81 mm. The light-emitting diode holder of the pointer was fixed into 2 Leila arms and moved under visual control based on CT images. The target point was selected, Leila arms fixed and a burr hole performed. The cannula was introduced to the target, being fitted with a depth stop in a length identical to that of the pointer on the screen. If necessary a second trajectory was easily selected. 49 patients underwent a frameless stereotactic biopsy. All targets except seven were superficial or in the white matter. In selected cases the biopsies were taken from deep-seated lesions. A histological diagnosis was obtained in 100% of the cases. Four cases deteriorated postoperatively, two of these related to intratumoral bleeding. Navigation is a simple and effective method to perform biopsies of superficial and relatively large lesions. Frame-based procedures are restricted to brainstem tumors and lesions less than 1.5 cm in diameter.
引用
收藏
页码:11 / 15
页数:5
相关论文
共 40 条
[1]   Neuronavigation - Impact on operating time [J].
Alberti, O ;
Dorward, NL ;
Kitchen, ND ;
Thomas, DGT .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) :44-48
[2]   COMPLICATIONS OF CT-GUIDED STEREOTAXIC BIOPSY OF INTRAAXIAL BRAIN-LESIONS [J].
BERNSTEIN, M ;
PARRENT, AG .
JOURNAL OF NEUROSURGERY, 1994, 81 (02) :165-168
[3]  
Bolger C, 1999, Comput Aided Surg, V4, P322, DOI 10.3109/10929089909148185
[4]   Image-guided surgery: applications to the cervical and thoracic spine and a review of the first 120 procedures [J].
Bolger, C ;
Wigfield, C .
JOURNAL OF NEUROSURGERY, 2000, 92 (02) :175-180
[5]   VARIABLES AFFECTING THE ACCURACY OF STEREOTAXIC LOCALIZATION USING COMPUTERIZED-TOMOGRAPHY [J].
BUCHOLZ, RD ;
HO, HW ;
RUBIN, JP .
JOURNAL OF NEUROSURGERY, 1993, 79 (05) :667-673
[6]  
COOK RJ, 1993, PERSPECT NEUROL SURG, V4, P131
[7]   Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies - Technical note [J].
Dorward, NL ;
Alberti, O ;
Palmer, JD ;
Kitchen, ND ;
Thomas, DGT .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :160-168
[8]   ISC VIEWING WAND SYSTEM [J].
DRAKE, JM ;
RUTKA, JT ;
HOFFMAN, HJ .
NEUROSURGERY, 1994, 34 (06) :1094-1097
[9]  
GALLOWAY R L JR, 1991, Biomedical Instrumentation and Technology, V25, P457
[10]  
Germano I M, 1998, Comput Aided Surg, V3, P33, DOI 10.3109/10929089809148126