Solitary Pulmonary Nodule on Helical Dynamic CT Scans: Analysis of the Enhancement Patterns Using a Computer-Aided Diagnosis (CAD) System

被引:12
作者
Choi, Eun Jung [1 ]
Jin, Gong Yong [1 ]
Han, Young Min [1 ]
Lee, Young Sun [1 ]
Kweon, Keun Sang [2 ]
机构
[1] Chonbuk Natl Univ Hosp, Dept Radiol, Chonbuk 561712, South Korea
[2] Chonbuk Natl Univ Hosp, Dept Prov, Chonbuk 561712, South Korea
关键词
Computers; diagnosis aid; Lung neoplasms; diagnosis; nodule;
D O I
10.3348/kjr.2008.9.5.401
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: We wanted to investigate the usefulness of a computer-aided diagnosis (CAD) system in assisting radiologists to diagnosis malignant solitary pulmonary nodules (SPNs), as compared with diagnosing SPNs with using direct personal drawing. Materials and Methods: Forty patients with SPNs were analyzed. After the pre-contrast scan was performed, an additional ten series of post-contrast images were obtained at 20-second intervals. Two investigators measured the attenuation values of the SPNs: a radiologist who drew the regions of interest (ROIs), and a technician who used a CAD system. The Bland and Altman plots were used to compare the net enhancement between a CAD system and direct personal drawing. The diagnostic characteristics of the malignant SPNs were calculated by considering the CAD and direct personal drawing and with using Fisher's exact test. Results: On the Bland and Altman plot, the net enhancement difference between the CAD system and direct personal drawing was not significant (within +/- 2 standard deriation). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosing malignant SPNs using CAD was 92%, 85%, 75%, 96% and 88%, respectively. The sensitivity, specificity, PPV, NPV and accuracy of diagnosing malignant SPNs using direct drawing was 92%, 89%, 79%, 92% and 88%, respectively. Conclusion: The CAD system was a useful tool for diagnosing malignant SPNs.
引用
收藏
页码:401 / 408
页数:8
相关论文
共 27 条
[1]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]
Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance [J].
Das, Marco ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Flohr, Thomas G. ;
Guendel, Lutz ;
Stanzel, Sven ;
Kraus, Thomas ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
RADIOLOGY, 2006, 241 (02) :564-571
[3]
Solitary pulmonary nodules: Part I. Morphologic evaluation for differentiation of benign and malignant lesions [J].
Erasmus, JJ ;
Connolly, JE ;
McAdams, HP ;
Roggli, VL .
RADIOGRAPHICS, 2000, 20 (01) :43-58
[4]
Automated lung nodule detection at low-dose CT: Preliminary experience [J].
Goo, JM ;
Lee, JW ;
Lee, HJ ;
Kim, S ;
Kim, JH ;
Im, JG .
KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) :211-216
[5]
Solitary pulmonary nodules: Detection, characterization, and guidance for further diagnostic workup and treatment [J].
Jeong, Yeong Joo ;
Yi, Chin A. ;
Lee, Kyung Soo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :57-68
[6]
Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT [J].
Jeong, YJ ;
Lee, KS ;
Jeong, SY ;
Chung, MJ ;
Shim, SS ;
Kim, H ;
Kwon, OJ ;
Kim, S .
RADIOLOGY, 2005, 237 (02) :675-683
[7]
Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: Initial experience [J].
Kim, KG ;
Goo, JM ;
Kim, JH ;
Lee, HJ ;
Min, BG ;
Bae, KT ;
Im, JG .
RADIOLOGY, 2005, 237 (02) :657-661
[8]
The potential contribution of a computer-aided detection system for lung nodule detection in multidetector row computed tomography [J].
Lee, JW ;
Goo, JM ;
Lee, HJ ;
Kim, JH ;
Kim, S ;
Kim, YT .
INVESTIGATIVE RADIOLOGY, 2004, 39 (11) :649-655
[9]
The solitary pulmonary nodule [J].
Leef, JL ;
Klein, JS .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2002, 40 (01) :123-+
[10]
The challenge of the solitary pulmonary nodule Diagnostic assessment with multislice spiral CT [J].
Marten, K ;
Grabbe, E .
CLINICAL IMAGING, 2003, 27 (03) :156-161