All-solid-state chloride sensors with poly(3-octylthiopene) matrix and trihexadecylmethylammonium chlorides as an ion exchanger salt

被引:24
作者
Sjöberg-Eerola, P
Bobacka, J
Sokalski, T
Mieczkowski, J
Ivaska, A
Lewenstam, A
机构
[1] Abo Akad Univ, Proc Chem Ctr, Lab Analyt Chem, FIN-20500 Turku, Finland
[2] Ctr Proc Analyt Chem & Sensor Technol, FIN-20500 Turku, Finland
[3] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
all-solid-state chemical sensor; chloride electrode; conducting polymer; potentiometry;
D O I
10.1002/elan.200302797
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
All-solid-state chloride sensors were prepared by incorporation of trihexadecyl-methylammonium chloride (THMACl) as an ion-exchanger salt into a conjugated polymer membrane, poly(3-octylthiophene) (POT). ne influence of additional membrane components, such as a lipophilic anion, (potassium tetrakis[3,5-bis(trifluoromethyl)phenyl] borate), poly(vinyl chloride) (PVC) or a plasticizer, (2-nitrophenyl octyl ether) were studied. The membrane components were dissolved in chloroform except for PVC, which was dissolved in tetrahydrofuran (THF). The membrane solution was deposited on glassy carbon (GC) by solution casting resulting in all-solid-state chloride sensors. The sensor characteristics were determined potentiometrically and with impedance spectroscopy. The addition of plasticizer was found to be crucial in obtaining a well functioning Cl--ISE based on POT and THMACl.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 15 条
[1]   Ion sensors: current limits and new trends [J].
Bakker, E ;
Diamond, D ;
Lewenstam, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :11-18
[2]   SINGLE PIECE ALL-SOLID-STATE ION-SELECTIVE ELECTRODE [J].
BOBACKA, J ;
LINDFORS, T ;
MCCARRICK, M ;
IVASKA, A ;
LEWENSTAM, A .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3819-3823
[3]   POTENTIOMETRIC RESPONSE OF POLY(3-OCTYLTHIOPHENE), POLY(3-METHYLTHIOPHENE) AND POLYTHIOPHENE IN AQUEOUS-SOLUTIONS [J].
BOBACKA, J ;
LEWENSTAM, A ;
IVASKA, A .
TALANTA, 1993, 40 (09) :1437-1444
[4]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[5]   Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :195-202
[6]   ELECTROCHEMICAL STUDY OF POLY(3-OCTYLTHIOPHENE) FILM ELECTRODES - IMPEDANCE OF THE POLYMER FILM SEMICONDUCTOR ELECTROLYTE INTERFACE [J].
BOBACKA, J ;
GRZESZCZUK, M ;
IVASKA, A .
ELECTROCHIMICA ACTA, 1992, 37 (10) :1759-1765
[7]   ALL-SOLID-STATE SODIUM-SELECTIVE ELECTRODE BASED ON A CALIXARENE IONOPHORE IN A POLY(VINYL CHLORIDE) MEMBRANE WITH A POLYPYRROLE SOLID CONTACT [J].
CADOGAN, A ;
GAO, ZQ ;
LEWENSTAM, A ;
IVASKA, A ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2496-2501
[8]  
HARTMAN K, 1978, MIKROCHIM ACTA, V11, P235
[9]   STUDIES OF QUATERNARY AMMONIUM ION INTERFERENCE ON POTASSIUM ION-SELECTIVE ELECTRODES [J].
LEWENSTAM, A ;
ERKOLA, E ;
LEHMENKUHLER, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :577-579
[10]   APPLICATION OF ION-SELECTIVE ELECTRODES IN CLINICAL ANALYSIS [J].
LEWENSTAM, A ;
MAJZURAWSKA, M ;
HULANICKI, A .
ELECTROANALYSIS, 1991, 3 (08) :727-734