Non-invasive continuous arterial pressure, heart rate and stroke volume measurements during graded head-up tilt in normal man

被引:20
作者
Critchley, LAH
Conway, F
Anderson, PJ
Tomlinson, B
Critchley, JAJH
机构
[1] CHINESE UNIV HONG KONG, PRINCE WALES HOSP, DEPT ANAESTHESIA & INTENS CARE, SHATIN, HONG KONG
[2] CHINESE UNIV HONG KONG, PRINCE WALES HOSP, DEPT CLIN PHARMACOL, SHATIN, HONG KONG
关键词
tilting; postural stress; monitoring; non-invasive; blood pressure; cardiac output; impedance cardiography; Finapres;
D O I
10.1007/BF02267754
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The haemodynamic effects of head-up tilt (HUT) at different tilt angles were investigated non-invasively in eight normal male subjects. Mean arterial pressure (MAP; by Ohmeda Finapres 2300), stroke volume (SV) and heart rate (HR; by BoMed NCCOM3-R7S) were continuously recorded whilst performing a series of HUTs (55 degrees, 10 degrees, 20 degrees, 30 degrees and 55 degrees) lasting 3 min each. The response to HUT was proportional to the sine of the tilt angle. The magnitude of the response varied between subjects. HUT to 55 degrees resulted in mean (95% confidence limits) increases in MAP by 16 (+/- 16)% and HR by 11 (+/- 24)% and a decrease in SV by -25 (+/- 22)%. These results were repeatable after 30 min. At small tilt angles, i.e. less than or equal to 20 degrees, MAP did not change and HR decreased by -3 (+/- 4)%. A detailed analysis revealed immediate dynamic (0-30 s), late dynamic (30-90 s) and plateau (after 90 s) phases in the response to HUT. In conclusion, HUT produces reproducible haemodynamic effects, although differences exist among subjects. A detailed analysis of these effects can be successfully performed using non-invasive methods.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 24 条
[21]   VARIABILITY IN CARDIOVASCULAR AND PLASMA NOREPINEPHRINE RESPONSES TO HEAD-UP TILT IN HEALTHY-HUMAN SUBJECTS [J].
VAZ, M ;
KUMAR, MVS ;
RODRIGUES, D ;
KULKARNI, RN ;
SHETTY, PS .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1991, 36 (03) :201-208
[22]   NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT DURING INDUCTION OF ANESTHESIA AND TRACHEAL INTUBATION - THIOPENTONE AND PROPOFOL COMPARED [J].
VOHRA, A ;
THOMAS, AN ;
HARPER, NJN ;
POLLARD, BJ .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (01) :64-68
[23]   NONINVASIVE CARDIAC-OUTPUT - SIMULTANEOUS COMPARISON OF 2 DIFFERENT METHODS WITH THERMODILUTION [J].
WONG, DH ;
TREMPER, KK ;
STEMMER, EA ;
OCONNOR, D ;
WILBUR, S ;
ZACCARI, J ;
REEVES, C ;
WEIDOFF, P ;
TRUJILLO, RJ .
ANESTHESIOLOGY, 1990, 72 (05) :784-792
[24]   COMPARISON OF THORACIC ELECTRICAL BIOIMPEDANCE AND THERMODILUTION FOR THE MEASUREMENT OF CARDIAC INDEX IN PATIENTS WITH SEVERE SEPSIS [J].
YOUNG, JD ;
MCQUILLAN, P .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (01) :58-62