Mechanical fatigue of thin copper foil

被引:77
作者
Merchant, HD [1 ]
Minor, MG
Liu, YL
机构
[1] Gould Elect, Eastlake, OH 44095 USA
[2] Univ Kentucky, Lexington, KY 40506 USA
关键词
copper foil; mechanical fatigue; Coffin-Manson relationship; electrodeposited;
D O I
10.1007/s11664-999-0176-x
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The electrodeposited and the rolled 12 to 35 mu m thick copper foils are subjected to the bending/unbending strain-controlled flex fatigue over a wide range of strain amplitudes. The fatigue life is associated with an increase in electrical resistance of the specimen beyond a preassigned threshold. For each foil type, in the rolled or as-deposited as well as in the (recrystallization-like) annealed conditions, the inverse Coffin-Manson (C-M) relationship between strain amplitude (Delta epsilon/2) and fatigue life (N-f) is established in the high Delta epsilon/2 (low N-f) and the low Delta epsilon/2 (high N-f) regimes. The N-f, Delta epsilon/2, and C-M slopes (c,b) are utilized to calculate the cyclic strain hardening (n') and fatigue ductility (D-f) parameters. It is shown that for a given foil thickness, an universal relationship exists between D-f and the strength (sigma) normalized fatigue life (N-f/sigma). The propagation of fatigue crack through the foil thickness and across the sample width is related to the unique fine grain structure for each foil type: pancaked grains for the rolled foil and equiaxed grains for the electrodeposited foil. The fatal failure corresponds to convergence of the through-thickness and the across-the-width fatigue cracks. The variations in (i) electrical resistance, (ii) mid-thickness microhardness and grain structure and (iii) dislocation configurations with fatigue are monitored. Except for a small but significant fatigue induced softening (or hardening), no convincing evidence of strain localization land the associated dislocation configurations generally observed for the bulk samples) has been found.
引用
收藏
页码:998 / 1007
页数:10
相关论文
共 28 条
[21]  
Meyers M.A., 1984, MECH METALLURGY PRIC, P688
[22]  
MORROW JD, 1996, ASTM STP, V378, P72
[23]   FATIGUE GAUGE UTILIZING SLIP-INITIATION PHENOMENON IN ELECTROPLATED COPPER FOIL [J].
NAGASE, Y ;
YOSHIZAKI, T .
EXPERIMENTAL MECHANICS, 1993, 33 (01) :49-54
[24]   A BASIC STUDY ON FATIGUE GAUGE MADE OF ELECTROPLATED COPPER FOIL - (EFFECTS OF UNDERSTRESS) [J].
NAGASE, Y ;
YOSHIZAKI, T .
JSME INTERNATIONAL JOURNAL SERIES I-SOLID MECHANICS STRENGTH OF MATERIALS, 1991, 34 (01) :56-63
[25]   OVERVIEW NO-89 - MECHANISM MAPS FOR CYCLIC PLASTICITY AND FATIGUE OF SINGLE-PHASE MATERIALS [J].
PEDERSEN, OB .
ACTA METALLURGICA ET MATERIALIA, 1990, 38 (07) :1221-1239
[26]   CYCLIC SOFTENING IN ANNEALED POLYCRYSTALLINE COPPER [J].
POLAK, J ;
OBRTLIK, K ;
HAJEK, M ;
VASEK, A .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1992, 154 (02) :L15-L18
[27]   CYCLIC STRESS-STRAIN RESPONSE OF POLYCRYSTALLINE COPPER IN A WIDE-RANGE OF PLASTIC STRAIN AMPLITUDES [J].
POLAK, J ;
OBRTLIK, K ;
HAJEK, M ;
VASEK, A .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1992, 151 (01) :19-27
[28]  
WATANABE R, 1990, COPPER 90, P535