Immune affinity extraction of pesticides from surface water

被引:9
作者
Houben, A
Meulenberg, E
Noij, T
Gronert, C
Stoks, P
机构
[1] WRK Water Works, NL-3430 AA Nieuwegein, Netherlands
[2] RIZA, NL-8200 AA Lelystad, Netherlands
[3] ELTI Support, NL-6546 MN Nijmegen, Netherlands
[4] Kiwa, NL-3430 BB Nieuwegein, Netherlands
[5] Mallinckrodt Baker, NL-7400 AA Deventer, Netherlands
关键词
immuno affinity; preconcentration; pesticides; surface water;
D O I
10.1016/S0003-2670(99)00577-2
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The polar nature of present-day pesticides and the low levels in surface water make them difficult to analyze using available analytical instrumentation. Preconcentration is generally required which makes such methods complex and costly. Immune affinity chromatography (IAC) seemed to be promising as a preconcentration technique due to the intrinsic selectivity and sensitivity of the underlying immunochemistry. The present study was, therefore, undertaken in order to find out whether a selective enrichment of a number of target pesticides could be achieved using IAC in a cast-effective way. Atrazine, 2,4-D, aldicarb and glyfosate were chosen as target pesticides and off-line columns were constructed using various antibodies and solid phases. These columns were evaluated regarding selectivity, recovery, capacity and certain other performance criteria, as well as the reusability. Pesticide analyses were done using immune assay as well as LC and/or GC. The results clearly demonstrate the potential application of IAC in pesticide analysis. Repeated use (>20 times) had no significant influence on column stability, provided certain precautions were taken. However, the performance of the columns varied depending on the type and the amount of antibody used. Off-line IAC columns appear to be particularly suited for qualitative or semiquantitative measurements, e.g. in the identification of 'hot spots'. Furthermore, the results indicate a potential for on-line applications where they may be useful for extracting, purifying and concentrating selected groups of polar pesticides from surface water samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 13 条
[1]
MONOCLONAL ELISA FOR 2,4-DICHLOROPHENOXYACETIC ACID - CHARACTERIZATION OF ANTIBODIES AND ASSAY OPTIMIZATION [J].
FRANEK, M ;
KOLAR, V ;
GRANATOVA, M ;
NEVORANKOVA, Z .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (06) :1369-1374
[2]
GUENU S, 1995, ANAL METHOD INSTRUM, V2, P247
[3]
HOPMAN TNR, 1996, H20, V29, P42
[4]
MARCX A, 1995, ANAL LETT, V28, P267
[5]
MARTLBAUER E, 1996, ACS SYM SER, V636, P121
[6]
*MIN TRANSP PUBL W, 1994, 21250 DUTCH PARL
[7]
*MIN TRANSP PUBL W, 1989, 3 NAT POL DOC WAT MA
[8]
MULDER W, 1991, H20, V24, P56
[9]
Norberg J., 1995, ANAL METHOD INSTRUM, V2, P266
[10]
ONLINE PRECONCENTRATION AND LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHENYLUREA PESTICIDES IN ENVIRONMENTAL WATER USING A SILICA-BASED IMMUNOSORBENT [J].
PICHON, V ;
CHEN, L ;
HENNION, MC .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :429-436