Optimal environment for glucose oxidase in perfluorosulfonated ionomer membranes: Improvement of first-generation biosensors

被引:136
作者
Karyakin, AA [1 ]
Kotel'nikova, EA
Lukachova, LV
Karyakina, EE
Wang, J
机构
[1] Moscow MV Lomonosov State Univ, Fac Chem, Moscow 119899, Russia
[2] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM 88003 USA
关键词
D O I
10.1021/ac0155409
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optimal environment for glucose oxidase (GOx) in Naflon membranes is achieved using an advanced immobilization protocol based on a nonaqueous immobilization route. Exposure of glucose oxidase to water-organic mixtures with a high (85-95%) content of the organic solvent resulted in stabilization of the enzyme by a membrane-forming polyelectrolyte. Such an optimal environment leads to the highest enzyme specific activity in the resulting membrane, as desired for optimal use of the expensive oxidases. Casting solution containing glucose oxidase and Naflon is completely stable over 5 days in a refrigerator, providing almost absolute reproducibility of GOx-Nafion membranes. A glucose biosensor was prepared by casting the GOx-Nafion membranes over Prussian Blue-modified glassy carbon disk electrodes. The biosensor operated in the FIA mode allows the detection of glucose down to the 0.1 muM level, along with high sensitivity (0.05 A M-1 cm(-2)), which is only 10 times lower than the sensitivity of the hydrogen peroxide transducer used. A comparison with the recently reported enzyme electrodes based on similar H2O2 transducers (transition metal hexacyanoferrates) shows that the proposed approach displays a dramatic (100-fold) improvement in sensitivity of the resulting biosensor. Combined with the attractive performance of a Prussian Blue-based hydrogen peroxide transducer, the proposed immobilization protocol provides a superior performance for first-generation glucose biosensors in term of sensitivity and detection limits.
引用
收藏
页码:1597 / 1603
页数:7
相关论文
共 41 条
[1]  
[Anonymous], 1990, STAT ANAL CHEM
[2]   High temperature stabilisation of immobilised glucose oxidase: potential applications in biosensors [J].
Appleton, B ;
Gibson, TD ;
Woodward, JR .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 43 (1-3) :65-69
[3]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[4]   Striking activation of oxidative enzymes suspended in nonaqueous media [J].
Dai, LZ ;
Klibanov, AM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (17) :9475-9478
[5]   Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode [J].
Deng, Q ;
Li, B ;
Dong, SJ .
ANALYST, 1998, 123 (10) :1995-1999
[6]   EVALUATION OF NAFION AS MEDIA FOR GLUCOSE-OXIDASE IMMOBILIZATION FOR THE DEVELOPMENT OF AN AMPEROMETRIC GLUCOSE BIOSENSOR [J].
FORTIER, G ;
VAILLANCOURT, M ;
BELANGER, D .
ELECTROANALYSIS, 1992, 4 (03) :275-283
[7]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[8]   Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer [J].
Garjonyte, R ;
Malinauskas, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :85-92
[9]   On protein denaturation in aqueous-organic mixtures but not in pure organic solvents [J].
Griebenow, K ;
Klibanov, AM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (47) :11695-11700
[10]  
Karyakin AA, 2001, ELECTROANAL, V13, P813, DOI 10.1002/1521-4109(200106)13:10<813::AID-ELAN813>3.0.CO