Effective time averaging of multiplexed measurements: A critical analysis

被引:14
作者
Bhargava, R [1 ]
Levin, IW [1 ]
机构
[1] NIDDK, Chem Phys Lab, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1021/ac011153n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multiplexing and time averaging of signal are effective noise reduction protocols applied in many analytical measurement systems. The efficacy of these protocols may be reduced by random occurrences of high-magnitude noise that do not conform to the statistical distribution of noise for all other measurements in the data set. This high-magnitude noise, which may have an insignificant probability of occurrence for a single measurement, almost certainly affects data collected in a multichannel, multiplexed modality, such as Fourier transform infrared (FT-IR) spectroscopic imaging employing focal plane array detectors. To recover time-averaging advantages in these cases, we present a general coaddition method that uses two statistical measures, the mean and median of the ensemble of measurements of a signal, to obtain a better estimate of the true signal than that estimated by time averaging alone. This method, termed median filtered time averaging, is shown to be an effective noise removal procedure for FT-IR imaging data. The effects of noise removal on time averaging and multiplexing are examined theoretically and are demonstrated for hyperspectral infrared microspectroscopic imaging data obtained from human skin biopsies by using a rapid data acquisition procedure.
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 16 条
[1]   Effect of focal plane array cold shield aperture size on fourier transform infrared micro-imaging spectrometer performance [J].
Bhargava, R ;
Fernandez, DC ;
Schaeberle, MD ;
Levin, IW .
APPLIED SPECTROSCOPY, 2000, 54 (12) :1743-1750
[2]   Fourier transform infrared imaging: Theory and practice [J].
Bhargava, R ;
Levin, IW .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5157-5167
[3]   Novel route to faster Fourier transform infrared spectroscopic imaging [J].
Bhargava, R ;
Schaeberle, MD ;
Fernandez, DC ;
Levin, IW .
APPLIED SPECTROSCOPY, 2001, 55 (08) :1079-1084
[4]   Processing FT-IR imaging data for morphology visualization [J].
Bhargava, R ;
Wang, SQ ;
Koenig, JL .
APPLIED SPECTROSCOPY, 2000, 54 (11) :1690-1706
[5]   Spike removal and denoising of Raman spectra by wavelet transform methods [J].
Ehrentreich, F ;
Sümmchen, L .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4364-4373
[6]  
GELADI P, 1996, MULTIVARIATE IMAGE A
[7]  
GRIFFITHS P, 1986, FOURIER TRANSFORM IN
[8]   IMPLICATIONS OF FLUCTUATION NOISE IN MULTIPLEX SPECTROSCOPY [J].
HIRSCHFELD, T .
APPLIED SPECTROSCOPY, 1976, 30 (02) :234-236
[9]   FELLGETTS ADVANTAGE IN UV-VIS MULTIPLEX SPECTROSCOPY [J].
HIRSCHFELD, T .
APPLIED SPECTROSCOPY, 1976, 30 (01) :68-69
[10]   FOURIER-TRANSFORM SPECTROSCOPIC IMAGING USING AN INFRARED FOCAL-PLANE ARRAY DETECTOR [J].
LEWIS, EN ;
TREADO, PJ ;
REEDER, RC ;
STORY, GM ;
DOWREY, AE ;
MARCOTT, C ;
LEVIN, IW .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3377-3381