Fourier transform infrared imaging: Theory and practice

被引:78
作者
Bhargava, R [1 ]
Levin, IW [1 ]
机构
[1] NIDDKD, Chem Phys Lab, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1021/ac010380m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The signal-to-noise ratio (SNR) of spectral data obtained from a microimaging Fourier transform infrared (FT-IR) spectrometer assembly, employing a step-scan interferometer and focal plane array detector, is analyzed. Based on the methodology of data collection, a theoretical description for the performance characteristics is proposed and quantitative effects of the acquisition parameters on the SNR are explained theoretically and compared to experiment. To obtain the best strategy for achieving either the highest SNR in a given time interval or for attaining a given SNR in the shortest time period, the concept of characteristic plots is introduced. The theoretical analysis is extended to Fr-IR microimaging employing continuous scan interferometers in which the advantages of fast image collection are enumerated, while SNR limitations arising from mirror positioning errors are discussed. A step-scan method is suggested for faster data collection in which an optimal detector response and SNR benefits are retained. Theoretically obtained SNRs based upon the expressions proposed in this paper predict experimentally determined values quite well and can be used to obtain an understanding of the required developments for improved performance. Finally, SNRs for both microimaging systems and conventional microspectroscopic instrumentation are compared.
引用
收藏
页码:5157 / 5167
页数:11
相关论文
共 28 条
[1]   Towards faster FT-IR imaging by reducing noise [J].
Bhargava, R ;
Ribar, T ;
Koenig, JL .
APPLIED SPECTROSCOPY, 1999, 53 (11) :1313-1322
[2]   Route to higher fidelity FT-IR imaging [J].
Bhargava, R ;
Wang, SQ ;
Koenig, JL .
APPLIED SPECTROSCOPY, 2000, 54 (04) :486-495
[3]   Effect of focal plane array cold shield aperture size on fourier transform infrared micro-imaging spectrometer performance [J].
Bhargava, R ;
Fernandez, DC ;
Schaeberle, MD ;
Levin, IW .
APPLIED SPECTROSCOPY, 2000, 54 (12) :1743-1750
[4]   FTIR imaging studies of a new two-step process to produce polymer dispersed liquid crystals [J].
Bhargava, R ;
Wang, SQ ;
Koenig, JL .
MACROMOLECULES, 1999, 32 (08) :2748-2760
[5]   FT-IR imaging of the interface in multicomponent systems using optical effects induced by differences in refractive index [J].
Bhargava, R ;
Wang, SQ ;
Koenig, JL .
APPLIED SPECTROSCOPY, 1998, 52 (03) :323-328
[6]   Novel route to faster Fourier transform infrared spectroscopic imaging [J].
Bhargava, R ;
Schaeberle, MD ;
Fernandez, DC ;
Levin, IW .
APPLIED SPECTROSCOPY, 2001, 55 (08) :1079-1084
[7]   Comparison of the FT-IR mapping and imaging techniques applied to polymeric systems [J].
Bhargava, R ;
Wall, BG ;
Koenig, JL .
APPLIED SPECTROSCOPY, 2000, 54 (04) :470-479
[8]   Processing FT-IR imaging data for morphology visualization [J].
Bhargava, R ;
Wang, SQ ;
Koenig, JL .
APPLIED SPECTROSCOPY, 2000, 54 (11) :1690-1706
[9]  
BHARGAVA R, IN PRESS APPL SPECTR
[10]   Fourier transform infrared microscopy: some advances in techniques for characterisation and structure-property elucidations of industrial material [J].
Chalmers, JM ;
Everall, NJ ;
Hewitson, K ;
Chesters, MA ;
Pearson, M ;
Grady, A ;
Ruzicka, B .
ANALYST, 1998, 123 (04) :579-586