Assessment of injection volume limits when using on-column focusing with microbore liquid chromatography

被引:80
作者
Mills, MJ
Maltas, J
Lough, WJ
机构
[1] UNIV SUNDERLAND,SCH HLTH SCI,SUNDERLAND SR1 3RG,DURHAM,ENGLAND
[2] GLAXO WELLCOME MED LTD,DEPT DRUG METAB,GREENFORD UB6 0HE,MIDDX,ENGLAND
关键词
on-column focusing; injection volume; indomethacin;
D O I
10.1016/S0021-9673(96)00753-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It had been ascertained that in the use of microbore liquid chromatography (LC) and on-column focusing (peak compression), there were advantages to be had in using the strongest eluting injection solvent that would still bring about on-column focusing. Tn such cases, it was found that the scope for the use of on-column focusing with microbore LC was greater than previously imagined. It has been possible to explain these results by considering on-column focusing to take place in two distinct phases, i.e. focusing of the sample band due to the injection solvent, followed by further focusing of the sample band by the sample solvent/mobile phase step gradient. In this context, an equation has been developed which provides a much more accurate estimate of the maximum allowable injection volume for a given injection solvent and mobile phase than has been possible until now.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 28 条
[1]   GRADIENT ELUTION IN NON-LINEAR PREPARATIVE LIQUID-CHROMATOGRAPHY [J].
ANTIA, FD ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :1-27
[2]   DETERMINATION OF TOLUENE DIISOCYANATE IN AIR USING MICRO LIQUID-CHROMATOGRAPHY WITH UV-DETECTION [J].
BRUNMARK, P ;
DALENE, M ;
SANGO, C ;
SKARPING, G ;
ERLANDSSON, P ;
DEWAELE, C .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1991, 3 (04) :371-375
[3]  
CHERVET JF, 1992, LC GC INT, V7, P33
[4]   A COMPARATIVE-STUDY OF LARGE VOLUME INJECTION TECHNIQUES FOR MICROBORE COLUMNS IN HPLC [J].
CLAESSENS, HA ;
KUYKEN, MAJ .
CHROMATOGRAPHIA, 1987, 23 (05) :331-336
[5]   ANALYTICAL SOLUTION OF THE IDEAL MODEL OF ELUTION CHROMATOGRAPHY IN THE CASE OF A BINARY MIXTURE WITH COMPETITIVE LANGMUIR ISOTHERMS .2. SOLUTION USING THE H-TRANSFORM [J].
GOLSHANSHIRAZI, S ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :125-151
[6]  
GUIOCHON G, 1984, J CHROMATOGR LIBR, V28, P1
[7]   UNUSUAL ANALYTE ADSORPTION EFFECTS ON INERT LC COMPONENTS [J].
HAMBLETON, P ;
LOUGH, WJ ;
MALTAS, J ;
MILLS, MJ .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (16) :3205-3217
[8]  
HOFFMAN NE, 1991, J LIQ CHROMATOGR, V14, P651, DOI 10.1080/01483919108049277
[9]   QUANTITATIVE ANALYSIS OF TRACE AMOUNTS OF ESTROGENIC STEROIDS IN PREGNANCY URINE BY COLUMN LIQUID-LIQUID CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
HUBER, JFK ;
HULSMAN, JAR ;
MEIJERS, CAM .
JOURNAL OF CHROMATOGRAPHY, 1971, 62 (01) :79-&
[10]   THEORETICAL-STUDY OF MULTICOMPONENT INTERFERENCES IN NON-LINEAR CHROMATOGRAPHY [J].
JACOBSON, S ;
GOLSHANSHIRAZI, S ;
KATTI, AM ;
CZOK, M ;
MA, ZD ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY, 1989, 484 :103-124