Sample pretreatment on microfabricated devices

被引:144
作者
Lichtenberg, J [1 ]
de Rooij, NF [1 ]
Verpoorte, E [1 ]
机构
[1] Univ Neuchatel, SAMLAB, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
sample pretreatment; microfabricated devices; miniaturized total analysis systems; sample preparation; purification; filtering; preconcentration; PCR; dialysis; labeling;
D O I
10.1016/S0039-9140(01)00593-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The integration of sample pretreatment into microfluidic devices represents one of the remaining hurdles towards achieving true miniaturized total analysis systems (muTAS). The challenge is made more complex by the enormous variation in samples to be analyzed. Moreover, the pretreatment technique has to be compatible with the analysis device to which it is coupled in terms of time, reagent and power consumption, as well as sample volume. This review provides a thorough overview of the developments in this field to date. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:233 / 266
页数:34
相关论文
共 133 条
[1]   Micromachined flow-through filter-chamber for chemical reactions on beads [J].
Andersson, H ;
van der Wijngaart, W ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :203-208
[2]   A minisonicator to rapidly disrupt bacterial spores for DNA analysis [J].
Belgrader, P ;
Hansford, D ;
Kovacs, GTA ;
Venkateswaran, K ;
Mariella, R ;
Milanovich, F ;
Nasarabadi, S ;
Okuzumi, M ;
Pourahmadi, F ;
Northrup, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4232-4236
[3]  
Belgrader P, 2001, ANAL CHEM, V73, P286, DOI 10.1021/ac000905v
[4]   A microfluidic cartridge to prepare spores for PCR analysis [J].
Belgrader, P ;
Okuzumi, M ;
Pourahmadi, F ;
Borkholder, DA ;
Northrup, MA .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :849-852
[5]   A micromachined double lumen microdialysis probe connector with incorporated sensor for on-line sampling [J].
Böhm, S ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :201-208
[6]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[7]   A planar microfabricated fluid [J].
Brody, JP ;
Osborn, TD ;
Forster, FK ;
Yager, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) :704-708
[8]   Diffusion-based extraction in a microfabricated device [J].
Brody, JP ;
Yager, P .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 58 (01) :13-18
[9]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[10]  
2-M