Miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion

被引:14
作者
Lim, TK [1 ]
Imai, S [1 ]
Matsunaga, T [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Tokyo 1848588, Japan
关键词
miniaturized amperometric flow immunoassay; glass fiber membrane; ferrocene-conjugated IgG; human chorionic gonadotrophin;
D O I
10.1002/bit.10158
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This paper describes a miniaturized amperometric flow immunoassay system using a glass fiber membrane modified with anion. The glass fiber membrane was functionally modified with gamma-glycidoxypropyltrimethoxysilane and sodium thiosulfate and was used for separation of protein. Anti-human chorionic gonadotrophin (HCG) immunoglobulin G (IgG) antibody conjugated with ferrocenemonocarboxylic acid (Fc), namely, Fc-conjugated IgG (Fc-IgG), was used as a novel analytical reagent. HCG and Fc-IgG complexes were separated from free Fc-IgG based on differences in isoelectric point (pI) using the glass fiber membrane modified with a thiosulfonyl acid functional group. The assay yields a linear relationship between current and HCG concentration in the range of 0-2000 mIU/mL. This simple technique enables the assay of HCG within 2 min. The modified glass fiber membrane was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free Fc-IgG. Free Fc-IgG recovered in this manner could be reused up to eight times without significant decreases in sensitivity. This miniaturized amperometric flow immunoassay requires only minute quantities of serum and generates highly reproducible results. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:758 / 763
页数:6
相关论文
共 43 条
[1]  
[Anonymous], ATLAS SPECTRAL DATA
[2]   Chemiluminescence-based detection:: principles and analytical applications in flowing streams and in immunoassays [J].
Baeyens, WRG ;
Schulman, SG ;
Calokerinos, AC ;
Zhao, Y ;
Campaña, AMG ;
Nakashima, K ;
De Keukeleire, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :941-953
[3]   Development of a plasma 17α-hydroxyprogesterone time resolved-fluorescence immunoassay involving a new biotinylated tracer [J].
Boudi, A ;
Giton, F ;
Galons, H ;
Eulry, B ;
Villette, JM ;
Soliman, H ;
Boudou, P ;
Fiet, J .
STEROIDS, 2000, 65 (02) :103-108
[4]  
BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
[5]   Development of an off line noncompetitive flow immunoassay for the determination of interleukin-8 in cell samples [J].
Burestedt, E ;
Kjellström, S ;
Emnéus, J ;
Marko-Varga, G .
ANALYTICAL BIOCHEMISTRY, 2000, 279 (01) :46-54
[6]   DIAGNOSIS OF ECTOPIC PREGNANCY BY VAGINAL ULTRASONOGRAPHY IN COMBINATION WITH A DISCRIMINATORY SERUM HCG LEVEL OF 1000-IU/1 (IRP) [J].
CACCIATORE, B ;
STENMAN, UH ;
YLOSTALO, P .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (10) :904-908
[7]  
CHUANLIANGA L, 1996, J CHROMATOGR B, V687, P213
[8]   MECHANISM OF DYE RESPONSE AND INTERFERENCE IN THE BRADFORD PROTEIN ASSAY [J].
COMPTON, SJ ;
JONES, CG .
ANALYTICAL BIOCHEMISTRY, 1985, 151 (02) :369-374
[9]   Electron transfer between ferrocene-modified Au/octadecanethiol/lipid BLM electrode and redox couples in solution [J].
Cui, XL ;
Jiang, DL ;
Diao, P ;
Li, JX ;
Tong, RT ;
Wang, XK .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1999, 48 (01) :243-247
[10]  
DENNY RC, 1982, DICT SPECTROSCOPY