Quantitative assessment of bone marrow attenuation values at MDCT: An objective tool for the detection of bone bruise related to occult sacral insufficiency fractures

被引:20
作者
Henes, F. O. [1 ]
Groth, M. [1 ]
Bley, T. A. [1 ]
Regier, M. [1 ]
Nuechtern, J. V. [2 ]
Ittrich, H. [1 ]
Treszl, A. [3 ]
Adam, G. [1 ]
Bannas, P. [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Radiol, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Dept Trauma Hand & Reconstruct Surg, D-20246 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Ctr Med Expt, Dept Med Biometry & Epidemiol, D-20246 Hamburg, Germany
关键词
MDCT; MRI; Bone bruises; Sacral insufficiency fractures; HU measurements; MULTISLICE CT; PAIN; CLASSIFICATION; SACROPLASTY; INJURIES; EDEMA; KNEE; MRI;
D O I
10.1007/s00330-012-2472-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To prove the feasibility of using Hounsfield attenuation values at MDCT to detect bone bruises related to sacral insufficiency fractures. Twenty-two patients with acute sacrum trauma and no fracture findings at MDCT were included in our prospective study. Two observers independently reviewed CTs regarding visual signs of bone bruises in 132 defined regions of the sacral alae. Interobserver agreement was tested by kappa statistics. Subsequently, HU values were obtained in the same regions, and attenuation differences between the two sides were calculated. Validity and reliability were assessed by intraclass correlation coefficient and Bland-Altman analysis. HU differences were subjected to ROC curve analysis to determine sensitivity, specificity, PPV and NPV. MRI served as standard reference. MRI revealed 19 regions with bone bruises and associated sacral insufficiency fractures. HU measurements demonstrated good validity and reliability (r = 0.989). ROC curve analysis exhibited an ideal cutoff value of 35.7 HU density difference between affected and non-affected regions. Visual evaluation revealed moderate agreement (kappa = 0.48); diagnostic accuracy was inferior to objective evaluation. Assessment of differences in bone marrow density by HU measurements is an objective and reliable tool for detection of bone bruises associated with occult sacral insufficiency fractures. aEuro cent Bone bruising is associated with occult sacral insufficiency fractures. aEuro cent Assessment of differences in bone marrow CT attenuation appears valid and reliable. aEuro cent Comparative HU measurements of bone marrow allow detection of bone bruises. aEuro cent Comparative HU measurements have high specificity and negative predictive values. aEuro cent Comparative HU measurements may make further diagnostic workup with MRI unnecessary.
引用
收藏
页码:2229 / 2236
页数:8
相关论文
共 29 条
[1]
Interventional Pain Relief Using Balloon-Kyphoplasty in Patients with Osteoporotic-Based Fatigue Fractures of the Os Sacrum [J].
Andresen, R. ;
Radmer, S. ;
Kamusella, P. ;
Wissgott, C. ;
Banzer, J. ;
Schober, H. C. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (01) :32-36
[2]
Sacral insufficiency fracture [J].
Blake, SP ;
Connors, AM .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (922) :891-896
[3]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]
Follow-up of occult bone lesions detected at MR imaging: Systematic review [J].
Boks, SS ;
Vroegindeweij, D ;
Koes, BW ;
Hunink, MGM ;
Bierma-Zeinstra, SMA .
RADIOLOGY, 2006, 238 (03) :853-862
[5]
Consequences of occult insufficiency fractures of the sacrum [J].
Briem, D. ;
Lehmann, W. ;
Grossterlinden, L. ;
Begemann, P. G. ;
Amling, M. ;
Rueger, J. M. .
UNFALLCHIRURG, 2007, 110 (12) :1068-1071
[6]
Musculoskeletal imaging with multislice CT [J].
Buckwalter, KA ;
Rydberg, J ;
Kopecky, KK ;
Crow, K ;
Yang, EL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) :979-986
[7]
Percutaneous sacroplasty for the treatment of sacral insufficiency fractures [J].
Butler, CL ;
Given, CA ;
Michel, SJ ;
Tibbs, PA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1956-1959
[8]
MRI and CT of Insufficiency Fractures of the Pelvis and the Proximal Femur [J].
Cabarrus, Miguel C. ;
Ambekar, Avanti ;
Lu, Ying ;
Link, Thomas M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) :995-1001
[9]
The limits of agreement and the intraclass correlation coefficient may be inconsistent in the interpretation of agreement [J].
Costa-Santos, Cristina ;
Bernardes, Joao ;
Ayres-de-Campos, Diogo ;
Costa, Antonia ;
Costa, Celia .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2011, 64 (03) :264-269
[10]
Culemann U, 2004, UNFALLCHIRURG, V107, P1169