Cyclic polyamide oligomers extracted from nylon 66 membrane filter disks as a source of contamination in liquid chromatography/mass spectrometry

被引:26
作者
Tran, JC [1 ]
Doucette, AA [1 ]
机构
[1] Dalhousie Univ, Dept Chem, Halifax, NS B3H 4J3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/j.jasms.2006.01.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background interferences are perhaps an unavoidable part of analytical detection schemes, particularly when analyzing trace level samples or when using detectors with high levels of sensitivity. In liquid chromatography, mobile phase solvents are routinely filtered using membrane filter disks to trap particulates in hopes of minimizing contamination, providing improvements in data output and instrumental operation. In this study, we report that one such filter disk leads to a significant level of contamination in LC and LC/MS experiments. Extractable compounds from nylon membrane filters generate significant background signals in UV absorption chromatograms at 214 nun, and are also detected by electrospray ionization mass spectrometry, with nominal m/z values of 453 and 679. It is shown that rinsing the nylon membranes before their use can reduce, but will not eliminate, the extractable contaminants from the mobile phase. Through MS and tandem MS analysis, we have identified these contaminants as cyclic oligomers of polyamide 66. Based on these results, it is recommended that nylon membrane filters be avoided when conducting trace level analysis, particularly when conducting LC/MS experiments.
引用
收藏
页码:652 / 656
页数:5
相关论文
共 27 条
[1]  
Aebi B, 1996, RAPID COMMUN MASS SP, V10, P947, DOI 10.1002/(SICI)1097-0231(19960610)10:8<947::AID-RCM609>3.0.CO
[2]  
2-B
[3]   MECHANISM OF THERMAL-DECOMPOSITION OF NYLON-66 [J].
BALLISTRERI, A ;
GAROZZO, D ;
GIUFFRIDA, M ;
MONTAUDO, G .
MACROMOLECULES, 1987, 20 (12) :2991-2997
[4]   IDENTIFICATION OF THE IONS PRODUCED BY FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY IN SOME POLYESTERS AND POLYAMIDES [J].
BALLISTRERI, A ;
GAROZZO, D ;
GIUFFRIDA, M ;
MONTAUDO, G .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :2024-2027
[5]  
BIKALES NM, 1969, ENCY POLYM SCI, V10, P460
[6]   TIME-OF-FLIGHT SECONDARY ION MASS-SPECTROMETRY OF NYLONS - DETECTION OF HIGH MASS FRAGMENTS [J].
BLETSOS, IV ;
HERCULES, DM ;
GREIFENDORF, D ;
BENNINGHOVEN, A .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2384-2388
[7]   DETECTION OF TRACE ORGANIC IMPURITIES IN BINARY SOLVENT SYSTEMS - SOLVENT PURITY TEST [J].
BRISTOL, DW .
JOURNAL OF CHROMATOGRAPHY, 1980, 188 (01) :193-204
[8]  
Burrell MC, 1997, SURF INTERFACE ANAL, V25, P799, DOI 10.1002/(SICI)1096-9918(199709)25:10<799::AID-SIA302>3.0.CO
[9]  
2-M
[10]   MALDI investigation of the photooxidation of nylon-66 [J].
Carroccio, S ;
Puglisi, C ;
Montaudo, G .
MACROMOLECULES, 2004, 37 (16) :6037-6049