Left ventricular parallel conductance during cardiac cycle in children with congenital heart disease

被引:16
作者
White, PA
Chaturvedi, RR
Shore, D
Lincoln, C
Szwarc, RS
Bishop, AJ
Oldershaw, PJ
Redington, AN
机构
[1] Natl Brompton Hosp, Dept Paediat Cardiol, London SW3 6NP, ENGLAND
[2] Natl Brompton Hosp, Dept Surg, London SW3 6NP, ENGLAND
[3] Natl Brompton Hosp, Dept Adult Cardiol, London SW3 6NP, ENGLAND
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1997年 / 273卷 / 01期
关键词
volume calibration;
D O I
10.1152/ajpheart.1997.273.1.H295
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study examines the accuracy of the conductance catheter technique and, in particular, parallel conductance [expressed as offset volume (V-c)] changes during the cardiac cycle in the human left ventricle. Two groups of patients were assessed: group 1, with an open atrial septal defect, and group 2, with an interventricular communication. In a subgroup, pre- and postoperative data were compared to assess the possible impact of shunting or anatomic considerations on our measurements. V, is normally obtained by a saline-dilution technique previously described by Baan et al. [V-c(Baan); J. Baan, E. T. Van der Velde, H. G. Debruin, G. J. Smeenk, J. Koops, A. D. Van Dijk, D. Temmerman, P. J. Senden, and B. Buis. Circulation 70: 812-823, 1984]. This does not take into account potential changes during the cardiac cycle. Four cardiac cycles were taken from the hypertonic saline washin and were divided into six equal isochrones between the maximum and mini mum first derivatives of left ventricular pressure (dP/dt(max) and dP/dt(min), respectively). The apparent ventricular volume was regressed against stroke volume for the corresponding cardiac cycle. The volume at the y-intercept corresponds to the V-c at each time interval [V-c(t)]. In group I, there was a variation in V-c(t) during systole, but the temporal changes were quite small, on the order of 4.28% (SD = 5.18%) of total corrected end-diastolic volume (mean maximal variation of 2.60 ml). Furthermore, the value of V-c obtained at dP/dt(max) was not significantly different from that obtained at dP/dt(min). For group 2 as a whole, mean V-c(Baan) did not change significantly with ventricular septal defect closure (preoperative, 8.85 +/- 11.1 ml; postoperative, 9.82 +/- 11.84 ml). Group 2 children also exhibited a systolic cyclical variation in V-c(t) similar to group 1. Finally, V-c(t) as a percentage of end-diastolic volume was no different when group 1 and group 2 were compared. We conclude that in the left ventricle, even in the presence of a left-to-right shunt, there is a small but insignificant difference in parallel conductance during ventricular ejection. The magnitude of this cyclical change does not preclude ventricular volume measurement in congenital heart disease by the conductance catheter technique.
引用
收藏
页码:H295 / H302
页数:8
相关论文
共 21 条
  • [1] SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (02) : 638 - 648
  • [2] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [5] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [6] THE CONDUCTANCE VOLUME CATHETER TECHNIQUE FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN YOUNG PIGLETS
    CASSIDY, SC
    TEITEL, DF
    [J]. PEDIATRIC RESEARCH, 1992, 31 (01) : 85 - 90
  • [7] DETECTION OF LEFT-VENTRICULAR REGIONAL MYOCARDIAL ISCHEMIA IN DOGS BY INTRAVENTRICULAR CONDUCTANCE CATHETER
    FISCHER, EIC
    SPINELLI, JC
    WILLSHAW, P
    CROTTOGINI, AJ
    DEFORTEZA, E
    CLAVIN, O
    VALENTINUZZI, ME
    PICHEL, RH
    [J]. CARDIOVASCULAR RESEARCH, 1988, 22 (03) : 185 - 192
  • [8] DYNAMIC DETERMINANTS OF LEFT-VENTRICULAR DIASTOLIC PRESSURE-VOLUME RELATIONS IN MAN
    GAASCH, WH
    COLE, JS
    QUINONES, MA
    ALEXANDER, JK
    [J]. CIRCULATION, 1975, 51 (02) : 317 - 323
  • [9] CONTRACTILE STATE OF LEFT-VENTRICLE IN MAN AS EVALUATED FROM END-SYSTOLIC PRESSURE-VOLUME RELATIONS
    GROSSMAN, W
    BRAUNWALD, E
    MANN, T
    MCLAURIN, LP
    GREEN, LH
    [J]. CIRCULATION, 1977, 56 (05) : 845 - 852
  • [10] FROM EMAX TO PRESSURE-VOLUME RELATIONS - A BROADER VIEW
    KASS, DA
    MAUGHAN, WL
    [J]. CIRCULATION, 1988, 77 (06) : 1203 - 1212