Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro

被引:76
作者
Kuiper, JW
vanKuijk, C
Grashuis, JL
Ederveen, AGH
Schutte, HE
机构
[1] UNIV HOSP DIJKZIGT,3015 GD ROTTERDAM,NETHERLANDS
[2] ORGANON INT BV,ORGANON SCI DEV GRP,DEPT ENDOCRINOL,OSS,NETHERLANDS
关键词
absorptiometry; accuracy; bone; comparative study; dual-energy X-ray; femur; in vitro; marrow fat; quantitative CT;
D O I
10.1007/BF01626534
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Bone mineral measurements with quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA) were compared with chemical analysis (ChA) to determine (1) the accuracy and (2) the influence of bone marrow fat. Total bone mass of 19 human femoral necks in vitro was determined with QCT and DXA before and after defatting. ChA consisted of defatting and decalcification of the femoral neck samples for determination of bone mineral mass (BmM) and amount of fat. The mean BmM was 4.49 g. Mean fat percentage was 37.2% (23.3%-48.5%). QCT, DXA and ChA before and after defatting were all highly correlated (r>0.96, p<0.0001). Before defatting the QCT values were on average 0.35 g less than BmM and the DXA values were on average 0.65 g less than BmM. After defatting, all bone mass values increased; QCT values were on average 0.30 g more than BmM and DXA values were 0.29 g less than BmM. It is concluded that bone mineral measurements of the femoral neck with QCT and DXA are highly correlated with the chemically determined bone mineral mass and that both techniques are influenced by the femoral fat content.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 22 条
[1]
BONE MASS-DISTRIBUTION IN THE LOWER LEG - A QUANTITATIVE COMPUTED TOMOGRAPHIC STUDY OF 36 INDIVIDUALS [J].
ALHO, A ;
HOISETH, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (05) :468-470
[2]
3-DIMENSIONAL QUANTITATIVE CT OF THE PROXIMAL FEMUR - RELATIONSHIP TO VERTEBRAL TRABECULAR BONE-DENSITY IN POSTMENOPAUSAL WOMEN [J].
BHASIN, S ;
SARTORIS, DJ ;
FELLINGHAM, L ;
ZLATKIN, MB ;
ANDRE, M ;
RESNICK, D .
RADIOLOGY, 1988, 167 (01) :145-149
[3]
DUAL ENERGY X-RAY ABSORPTIOMETRY - THE EFFECTS OF BEAM HARDENING ON BONE-DENSITY MEASUREMENTS [J].
BLAKE, GM ;
MCKEENEY, DB ;
CHHAYA, SC ;
RYAN, PJ ;
FOGELMAN, I .
MEDICAL PHYSICS, 1992, 19 (02) :459-465
[4]
BONE LOSS AFTER LOCKED INTRAMEDULLARY NAILING - COMPUTED-TOMOGRAPHY OF THE FEMUR AND TIBIA IN 10 CASES [J].
BRATEN, M ;
NORDBY, A ;
TERJESEN, T ;
ROSSVOLL, I .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (03) :310-314
[5]
QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[6]
QUANTITATIVE HISTOLOGICAL STUDIES ON AGE CHANGES IN BONE [J].
DUNNILL, MS ;
ANDERSON, JA ;
WHITEHEAD, R .
JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1967, 94 (02) :275-+
[7]
ESSES SI, 1989, J BONE MINER RES, V4, P715
[8]
CROSS-CALIBRATION OF LIQUID AND SOLID QCT CALIBRATION STANDARDS - CORRECTIONS TO THE UCSF NORMATIVE DATA [J].
FAULKNER, KG ;
GLUER, CC ;
GRAMPP, S ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1993, 3 (01) :36-42
[9]
QUANTITATIVE BONE-MINERAL ANALYSIS USING DUAL ENERGY COMPUTED TOMOGRAPHY [J].
GENANT, HK ;
BOYD, D .
INVESTIGATIVE RADIOLOGY, 1977, 12 (06) :545-551
[10]
EVALUATION OF A NEW SET OF CALIBRATION STANDARDS FOR THE MEASUREMENT OF FAT-CONTENT VIA DPA AND DXA [J].
GOODSITT, MM .
MEDICAL PHYSICS, 1992, 19 (01) :35-44