Restoring forces assessed with left atrial pressure clamps

被引:9
作者
Bell, SP [1 ]
Fabian, J [1 ]
Higashiyama, A [1 ]
Chen, ZY [1 ]
Tischler, MD [1 ]
Watkins, MW [1 ]
LeWinter, MM [1 ]
机构
[1] UNIV VERMONT, COLL MED, CARDIOL UNIT, BURLINGTON, VT 05405 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1996年 / 270卷 / 03期
关键词
ventricular mechanics; ventricular suction; diastolic function; isovolumic relaxation;
D O I
10.1152/ajpheart.1996.270.3.H1015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A negative pressure (P) in the fully relaxed left ventricle (LV) indicates the presence of restoring farces generated during contraction. To assess restoring forces in the intact LV under physiological filling conditions, a servomotor system was used in anesthetized open-chest dogs (n = 8) to produce nonfilling diastoles by left. atrial pressure (LAP) clamping during systole such that LAP was less than left ventricular pressure (LVP) during the subsequent diastole. Steady-state LV end-diastolic pressure (EDP) was varied by volume infusion from 4.0 +/- 1.5 (+/-SD) to 12.8 +/- 2.1 mmHg. The corresponding fully relaxed LVPs increased from -2.1 +/- 1.9 to 1.1 +/- 3.2 mmHg, P < 0.001. LAP clamping increased the rate of LVP fall by 34 +/- 28% (P < 0.001) during 10 ms after the LVP dropped below the level of the LVP-LAP crossover of the preceding normal beat. During clamped beats, two-dimensional echo revealed substantial downward displacement of the mitral valve (MV) leaflets despite the reversed LA-LV gradient and absence of filling. Thus 1) restoring forces are present at low physiological EDP but absent at high physiological EDP; 2) filling retards the rate of fall of LVP; 3) even in the absence of filling, the process of LV relaxation facilitates MV opening.
引用
收藏
页码:H1015 / H1020
页数:6
相关论文
共 19 条
[1]   PHASIC MITRAL BLOOD-FLOW AND REGIONAL LEFT-VENTRICULAR DIMENSIONS - POSSIBLE MECHANISM OF ACTIVE ASSIST TO VENTRICULAR FILLING [J].
BERTHA, BG ;
FOLTS, JD .
CIRCULATION, 1986, 74 (04) :901-911
[2]   LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE [J].
BOLTWOOD, CM ;
APPLEYARD, RF ;
GLANTZ, SA .
CIRCULATION, 1989, 80 (05) :1360-1377
[3]   CRITICAL REVIEW OF RECENT WORK ON VENTRICULAR DIASTOLIC SUCTION [J].
BRECHER, GA .
CIRCULATION RESEARCH, 1958, 6 (05) :554-566
[4]   RELAXATION AND DIASTOLE OF THE HEART [J].
BRUTSAERT, DL ;
SYS, SU .
PHYSIOLOGICAL REVIEWS, 1989, 69 (04) :1228-1315
[5]   THE SINUS NODE INHIBITOR UL-FS-49 LACKS SIGNIFICANT INOTROPIC EFFECT [J].
CHEN, ZY ;
SLINKER, BK .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1992, 19 (02) :264-271
[6]   LEFT-VENTRICULAR FUNCTION IN CHRONIC MITRAL REGURGITATION - PREOPERATIVE AND POSTOPERATIVE COMPARISON [J].
CORIN, WJ ;
SUTSCH, G ;
MURAKAMI, T ;
KROGMANN, ON ;
TURINA, M ;
HESS, OM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (01) :113-121
[7]  
EBSTEIN E, 1904, ERGEB PHYSL, V3, P123
[8]  
Glantz SA, 1990, PRIMER APPL REGRESSI, P381
[9]   VALVULAR-VENTRICULAR INTERACTION - IMPORTANCE OF THE MITRAL APPARATUS IN CANINE LEFT-VENTRICULAR SYSTOLIC PERFORMANCE [J].
HANSEN, DE ;
CAHILL, PD ;
DECAMPLI, WM ;
HARRISON, DC ;
DERBY, GC ;
MITCHELL, RS ;
MILLER, DC .
CIRCULATION, 1986, 73 (06) :1310-1320
[10]   LEFT-VENTRICULAR DIASTOLIC SUCTION AS A MECHANISM OF VENTRICULAR FILLING [J].
HORI, M ;
YELIIN, EL ;
SONNENBLICK, EH .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (01) :124-129