Integration of positron emission tomography/computed tomography with electroanatomical mapping: A novel approach for ablation of scar-related ventricular tachycardia

被引:37
作者
Fahmy, Tamer S. [2 ,3 ]
Wazni, Oussama M. [2 ]
Jaber, Wael A. [2 ]
Walimbe, Vivek [2 ]
Di Biase, Luigi [2 ,4 ]
Elayi, CLaude S. [2 ]
DiFilippo, Frank P. [2 ]
Young, Ron B. [2 ]
Patel, Dimpi [2 ]
Riedlbauchova, Lucie [2 ]
Corrado, Andrea [2 ]
Burkhardt, J. David [2 ]
Schweikert, Robert A. [2 ]
Arruda, Mauricio [2 ]
Natale, Andrea [1 ,2 ,5 ]
机构
[1] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX USA
[2] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH USA
[3] Cairo Univ, Dept Crit Care Med, Cairo, Egypt
[4] Univ Foggia, Dept Cardiol, Foggia, Italy
[5] Stanford Univ, Palo Alto, CA 94304 USA
关键词
Ventricular tachycardia; Radiofrequency ablation; Image integration; PET/CT; Electroanatomical mapping;
D O I
10.1016/j.hrthm.2008.08.020
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
BACKGROUND Despite the recent advances in cardiac mapping, ablation of scar-related ventricular tachycardia (VT) still remains a clinical challenge. A detailed electroanatomical map is a prerequisite for accurate Localization and ablation of the VT substrate. OBJECTIVE The purpose of this study was to evaluate the feasibility and accuracy of integrating the positron emission tomography (PET)/computed tomography (CT) with the electroanatomical map and compare the accuracy of the voltage-based scar with the biological scar. METHODS Patients undergoing radiofrequency ablation (n = 19) for scar-related VT were enrolled. CT angiography and PET scans were performed for all patients. Tomographic and volumetric data from both images were processed and coregistered using internally designed software. That image was segmented in an electrophysiology mapping system and registered to the electroanatomical map. Eight different thresholds were applied on the voltage map to define the scar. The surface areas of the biological and electrical dense scars at different thresholds were measured and compared. RESULTS The PET/CT image was well integrated with the electroanatomical map with a mean surface registration error of 5.1 +/- 2.1 mm. Of the eight different thresholds defining the scar, the surface area of the scar at a threshold of 0.9 mV (68.6 +/- 49.2 cm(2)) correlated best with the surface area of the PET-based scar (70.4 +/- 49.3 cm(2)) and had the least total area error (4.8 +/- 1.8 cm(2)) compared with the 0.5 threshold (29.7 +/- 23.9 cm(2)). CONCLUSION Integrating PET/CT with the electroanatomical map is feasible and accurate. Based on the biological scar, readjustment of the voltage scar threshold to 0.9 mV is suggested. In view of the better accuracy of PET/CT in defining scar, the need for acquiring detailed voltage maps may be obviated.
引用
收藏
页码:1538 / 1545
页数:8
相关论文
共 26 条
[1]
Botker HE, 2001, CIRCULATION, V103, P1631
[2]
Electroanatomic left ventricular mapping in the porcine model of healed anterior myocardial infarction - Correlation with intracardiac echocardiography and pathological analysis [J].
Callans, DJ ;
Ren, JF ;
Michele, J ;
Marchlinski, FE ;
Dillon, SM .
CIRCULATION, 1999, 100 (16) :1744-1750
[3]
Assessment of infarct size by positron emission tomography and [18F]2-fluoro-2-deoxy-D-glucose:: a new absolute threshold technique [J].
Chareonthaitawee, I ;
Schaefers, K ;
Baker, CSR ;
Turkheimer, F ;
Stegger, L ;
Banner, NR ;
Yacoub, M ;
Bonser, RS ;
Iozzo, P ;
Camici, PG ;
Rimoldi, O .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (02) :203-215
[4]
VALUE OF METABOLIC IMAGING WITH POSITRON EMISSION TOMOGRAPHY FOR EVALUATING PROGNOSIS IN PATIENTS WITH CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR DYSFUNCTION [J].
DICARLI, MF ;
DAVIDSON, M ;
LITTLE, R ;
KHANNA, S ;
MODY, FV ;
BRUNKEN, RC ;
CZERNIN, J ;
ROKHSAR, S ;
STEVENSON, LW ;
LAKS, H ;
HAWKINS, R ;
SCHELBERT, HR ;
PHELPS, ME ;
MADDAHI, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (08) :527-533
[5]
Integration of Three-Dimensional Scar Maps for Ventricular Tachycardia Ablation With Positron Emission Tomography-Computed Tomography [J].
Dickfeld, Timm ;
Lei, Peng ;
Dilsizian, Vasken ;
Jeudy, Jean ;
Dong, Jun ;
Voudouris, Apostolos ;
Peters, Robert ;
Saba, Magdi ;
Shekhar, Raj ;
Shorofsky, Stephen .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (01) :73-82
[6]
Intracardiac echo-guided image integration: Optimizing strategies for registration [J].
Fahmy, Tamer S. ;
Mlcochova, Hanka ;
Wazni, Oussama M. ;
Patel, Dimpi ;
Cihak, Robert ;
Kanj, Mohamed ;
Beheiry, Salwa ;
Burkhardt, J. David ;
Dresing, Thomas ;
Hao, Steven ;
Tchou, Patrick ;
Kautzner, Josef ;
Schweikert, Robert A. ;
Arruda, Mauricio ;
Saliba, Walid ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (03) :276-282
[7]
Comparison of endocardial electromechanical mapping with radionuclide perfusion imaging to assess myocardial viability and severity of myocardial ischemia in angina pectoris [J].
Fuchs, S ;
Hendel, RC ;
Baim, DS ;
Moses, JW ;
Pierre, A ;
Laham, RJ ;
Hong, MK ;
Kuntz, RE ;
Pietrusewicz, M ;
Bonow, RO ;
Mintz, GS ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (07) :874-880
[8]
Positron emission tomography using 18F-fluoro-deoxyglucose and euglycaemic hyperinsulinaemic glucose clamp:: optimal criteria for the prediction of recovery of post-ischaemic left ventricular dysfunction -: Results from the European Community Concerted Action Multicenter study on use of 18F-fluoro-deoxyglucose Positron Emission Tomography for the Detection of Myocardial Viability [J].
Gerber, BL ;
Ordoubadi, FF ;
Wijns, W ;
Vanoverschelde, JLJ ;
Knuuti, MJ ;
Janier, M ;
Melon, P ;
Blanksma, PK ;
Bol, A ;
Bax, JJ ;
Melin, JA ;
Camici, PG .
EUROPEAN HEART JOURNAL, 2001, 22 (18) :1691-1701
[9]
Graf S, 2004, J NUCL MED, V45, P1611
[10]
Preoperative positron emission tomographic viability assessment and perioperative and postoperative risk in patients with advanced ischemic heart disease [J].
Haas, F ;
Haehnel, CJ ;
Picker, W ;
Nekolla, S ;
Martinoff, S ;
Meisner, H ;
Schwaiger, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1693-1700