Integration of Three-Dimensional Scar Maps for Ventricular Tachycardia Ablation With Positron Emission Tomography-Computed Tomography

被引:75
作者
Dickfeld, Timm [1 ,2 ]
Lei, Peng [1 ]
Dilsizian, Vasken [1 ]
Jeudy, Jean [1 ]
Dong, Jun [2 ]
Voudouris, Apostolos [1 ]
Peters, Robert [1 ]
Saba, Magdi [1 ]
Shekhar, Raj [1 ]
Shorofsky, Stephen [1 ]
机构
[1] Univ Maryland, Dept Cardiol, Baltimore, MD 21201 USA
[2] Johns Hopkins Univ, Div Cardiol, Baltimore, MD USA
关键词
D O I
10.1016/j.jcmg.2007.10.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to assess the feasibility of deriving 3-dimensional (3D) scar maps from positron emission tomography (PET)/computed tomography (CT) hybrid imaging and to integrate those into clinical mapping systems to assist in ventricular tachycardia (VT) ablations. BACKGROUND Ablation strategies for nonidiopathic VT are increasingly based on the anatomic information of the scar and its border zone. However, the current "gold standard" of voltage mapping is limited by its inability to accurately describe a complex 3D scar morphology, its imperfect spatial resolution, and prolonged procedure times. METHODS Fourteen patients underwent PET/CT multimodality imaging before the VT ablation. We used PET/CT-derived scar maps to characterize myocardial scar using a 17-segment analysis and surface reconstruction. In 10 patients, reconstructed 3D metabolic scar maps were integrated into a clinical mapping system and compared with high-resolution voltage maps. RESULTS A good correlation was found between the voltage maps and PET/CT-derived scar maps (r = 0.89; r < 0.05). In addition, 3D metabolic scar maps accurately displayed endocardial and epicardial surface and could be successfully integrated with a registration error of 3.7 +/- 0.7 mm. A combination of visual alignment and surface registration was most accurate for myocardial scar accounting for <= 15% of the left ventricular surface. Scar size, location, and border zone accurately predicted high-resolution voltage map findings (r = 0.87; p < 0.05). Integrated scar maps revealed metabolically active channels within the myocardial scar not detected by voltage mapping and correctly predicted non-transmural scar despite normal endocardial voltage recordings. Areas of low voltage within wall segments displaying preserved metabolic activity were shown to be due to suboptimal catheter contact and prevented unnecessary ablation lesions. CONCLUSIONS We found that PET/CT fusion imaging is able to accurately assess left ventricular scar and its border zone. The integration of a 3D scar map into a clinical mapping system is feasible and may allow supplementary scar characterization that is not available from voltage maps. This technique could significantly facilitate substrate-based VT ablations. (J Am Coll Cardiol Img 2008;1:73-82) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:73 / 82
页数:10
相关论文
共 28 条
[1]   A feasibility study of contrast enhancement of acute myocardial infarction in multislice computed tomography -: Comparison with magnetic resonance imaging and gross morphology in pigs [J].
Buecker, A ;
Katoh, M ;
Krombach, GA ;
Spuentrup, E ;
Bruners, P ;
Günther, RW ;
Niendorf, TF ;
Mahnken, AH .
INVESTIGATIVE RADIOLOGY, 2005, 40 (11) :700-704
[2]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[3]   REGIONAL BLOOD-FLOW, OXIDATIVE-METABOLISM, AND GLUCOSE-UTILIZATION IN PATIENTS WITH RECENT MYOCARDIAL-INFARCTION [J].
CZERNIN, J ;
PORENTA, G ;
BRUNKEN, R ;
KRIVOKAPICH, J ;
CHEN, K ;
BENNETT, R ;
HAGE, A ;
FUNG, C ;
TILLISCH, J ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1993, 88 (03) :884-895
[4]   PREOPERATIVE PREDICTION OF THE OUTCOME OF CORONARY REVASCULARIZATION USING POSITRON EMISSION TOMOGRAPHY [J].
DESILVA, R ;
YAMAMOTO, Y ;
RHODES, CG ;
IIDA, H ;
NIHOYANNOPOULOS, P ;
DAVIES, GJ ;
LAMMERTSMA, AA ;
JONES, T ;
MASERI, A .
CIRCULATION, 1992, 86 (06) :1738-1742
[5]   Stereotactic catheter navigation using magnetic resonance image integration in the human heart [J].
Dickfeld, T ;
Calkins, H ;
Bradley, D ;
Solomon, SB .
HEART RHYTHM, 2005, 2 (04) :413-415
[6]   Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time [J].
Dickfeld, T ;
Calkins, H ;
Zviman, M ;
Kato, R ;
Meininger, G ;
Lickfett, L ;
Berger, R ;
Halperin, H ;
Solomon, SB .
CIRCULATION, 2003, 108 (19) :2407-2413
[7]   Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium [J].
Dickfeld, T ;
Calkins, H ;
Zviman, M ;
Meininger, G ;
Lickfett, L ;
Roguin, A ;
Lardo, AC ;
Berger, R ;
Halperin, H ;
Solomon, SB .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (02) :105-115
[8]   Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations [J].
Dong, J ;
Calkins, H ;
Solomon, SB ;
Lai, SH ;
Dalal, D ;
Lardo, A ;
Brem, E ;
Preiss, A ;
Berger, RD ;
Halperin, H ;
Dickfeld, T .
CIRCULATION, 2006, 113 (02) :186-194
[9]   Food and drug administration perspective - Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients [J].
Faris, Owen P. ;
Shein, Mitchell .
CIRCULATION, 2006, 114 (12) :1232-1233
[10]   Characterization of acute and chronic myocardial infarcts by multidetector computed tomography - Comparison with contrast-enhanced magnetic resonance [J].
Gerber, BL ;
Belge, B ;
Legros, GJ ;
Lim, P ;
Poncelet, A ;
Pasquet, AS ;
Gisellu, G ;
Coche, E ;
Vanoverschelde, JLJ .
CIRCULATION, 2006, 113 (06) :823-833