A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis

被引:190
作者
Diao, JP
Young, L
Kim, S
Fogarty, EA
Heilman, SM
Zhou, P
Shuler, ML
Wu, MM [1 ]
DeLisa, MP
机构
[1] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
[2] Cornell Univ, Sch Chem & Biomol Engn, Ithaca, NY 14853 USA
[3] Kionix Inc, Ithaca, NY 14850 USA
[4] Cornell Univ, Dept Biomed Engn, Ithaca, NY 14853 USA
关键词
D O I
10.1039/b511958h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a prototype three-channel microfluidic chip that is capable of generating a linear concentration gradient within a microfluidic channel and is useful in the study of bacterial chemotaxis. The linear chemical gradient is established by diffusing a chemical through a porous membrane located in the side wall of the channel and can be established without through-flow in the channel where cells reside. As a result, movement of the cells in the center channel is caused solely by the cells chemotactic response and not by variations in fluid flow. The advantages of this microfluidic chemical linear gradient generator are (i) its ability to produce a static chemical gradient, (ii) its rapid implementation, and (iii) its potential for highly parallel sample processing. Using this device, wildtype Escherichia coli strain RP437 was observed to move towards an attractant ( e. g., L-asparate) and away from a repellent ( e. g., glycerol) while derivatives of RP437 that were incapable of motility or chemotaxis showed no bias of the bacteria's distribution. Additionally, the degree of chemotaxis could be easily quantified using this assay in conjunction with fluorescence imaging techniques, allowing for estimation of the chemotactic partition coefficient (CPC) and the chemotactic migration coefficient (CMC). Finally, using this approach we demonstrate that E. coli deficient in autoinducer-2-mediated quorum sensing respond to the chemoattractant L-aspartate in a manner that is indistinguishable from wildtype cells suggesting that chemotaxis is insulated from this mode of cell-cell communication.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 44 条
  • [11] Structural identification of a bacterial quorum-sensing signal containing boron
    Chen, X
    Schauder, S
    Potier, N
    Van Dorsselaer, A
    Pelczer, I
    Bassler, BL
    Hughson, FM
    [J]. NATURE, 2002, 415 (6871) : 545 - 549
  • [12] FACS-optimized mutants of the green fluorescent protein (GFP)
    Cormack, BP
    Valdivia, RH
    Falkow, S
    [J]. GENE, 1996, 173 (01) : 33 - 38
  • [13] DNA microarray-based identification of genes controlled by autoinducer 2-stimulated quorum sensing in Escherichia coli
    DeLisa, MP
    Wu, CF
    Wang, L
    Valdes, JJ
    Bentley, WE
    [J]. JOURNAL OF BACTERIOLOGY, 2001, 183 (18) : 5239 - 5247
  • [14] Generation of gradients having complex shapes using microfluidic networks
    Dertinger, SKW
    Chiu, DT
    Jeon, NL
    Whitesides, GM
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (06) : 1240 - 1246
  • [15] REPELLENTS FOR ESCHERICHIA-COLI OPERATE NEITHER BY CHANGING MEMBRANE FLUIDITY NOR BY BEING SENSED BY PERIPLASMIC RECEPTORS DURING CHEMOTAXIS
    EISENBACH, M
    CONSTANTINOU, C
    ALONI, H
    SHINITZKY, M
    [J]. JOURNAL OF BACTERIOLOGY, 1990, 172 (09) : 5218 - 5224
  • [16] Eisenbach M., 2004, Chemotaxis
  • [17] MEASUREMENT OF BACTERIAL RANDOM MOTILITY AND CHEMOTAXIS COEFFICIENTS .1. STOPPED-FLOW DIFFUSION CHAMBER ASSAY
    FORD, RM
    PHILLIPS, BR
    QUINN, JA
    LAUFFENBURGER, DA
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (07) : 647 - 660
  • [18] MEASUREMENT OF BACTERIAL RANDOM MOTILITY AND CHEMOTAXIS COEFFICIENTS .2. APPLICATION OF SINGLE-CELL-BASED MATHEMATICAL-MODEL
    FORD, RM
    LAUFFENBURGER, DA
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (07) : 661 - 672
  • [19] Generation of solution and surface gradients using microfluidic systems
    Jeon, NL
    Dertinger, SKW
    Chiu, DT
    Choi, IS
    Stroock, AD
    Whitesides, GM
    [J]. LANGMUIR, 2000, 16 (22) : 8311 - 8316
  • [20] Neutrophil chemotaxis in linear and complex gradients of interleukin-8 formed in a microfabricated device
    Jeon, NL
    Baskaran, H
    Dertinger, SKW
    Whitesides, GM
    Van de Water, L
    Toner, M
    [J]. NATURE BIOTECHNOLOGY, 2002, 20 (08) : 826 - 830