Biomechanical comparison between BioScrew and titanium alloy interference screws for bone-patellar tendon-bone graft fixation in anterior cruciate ligament reconstruction

被引:81
作者
Caborn, DNM
Urban, WP
Johnson, DL
Nyland, J
Pienkowski, D
机构
[1] Section of Sports Medicine, Division of Orthopaedic Surgery, Univ. of Kentucky Sch. of Medicine, Lexington, KY
[2] Univ. of Kentucky Sports Medicine, K437 Kentucky Clinic, Lexington
来源
ARTHROSCOPY | 1997年 / 13卷 / 02期
关键词
anterior cruciate ligament reconstruction; graft fixation; interference screw;
D O I
10.1016/S0749-8063(97)90159-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This investigation compared the maximum load at failure of BioScrew (Linvatec Corp, Large, FL) and titanium ahoy interference screw femoral fixation using a human cadaveric model that approximated the anatomical orientation and physiological strain rate of in vivo bone-patellar tendon-bone (BPTB) graft loading following anterior cruciate ligament reconstruction. Eighteen fresh-frozen human BPTB allografts (10-mm wide, 10-mm thick, 25-mm long bone plugs) with either BioScrew or titanium alloy (Ti 6A14V) screw (7 x 25 mm) fixation were compared for maximum load at failure at a strain rate of 20 mm/minute. Nine cadaver femurs with bone mineral densities of 0.88 +/- 0.18 g/cm(2) (anterior/posterior) and 1.3 +/- 0.24 g/cm(2) (lateral) received the allografts. No statistical differences were observed in maximum load at failure (P = .95) or failure mode (P = .11) between specimens fixed with either screw type. When biomechanically tested with anatomic orientation and at functionally relevant strain rates, the BioScrew provided maximum load at failure equal to a titanium alloy screw.
引用
收藏
页码:229 / 232
页数:4
相关论文
共 20 条
[1]   ARTHROMETRIC RESULTS OF ARTHROSCOPICALLY ASSISTED ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION USING AUTOGRAFT PATELLAR TENDON SUBSTITUTION [J].
BACH, BR ;
JONES, GT ;
HAGER, CA ;
SWEET, FA ;
LUERGANS, S .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (02) :179-185
[2]  
BACH BR, 1989, AM J KNEE SURG, V2, P76
[3]   THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS [J].
BLEVINS, FT ;
HECKER, AT ;
BIGLER, GT ;
BOLAND, AL ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) :328-333
[4]   THE BIOMECHANICS OF INTERFERENCE SCREW FIXATION OF PATELLAR TENDON ANTERIOR CRUCIATE LIGAMENT GRAFTS [J].
BROWN, CH ;
HECKER, AT ;
HIPP, JA ;
MYERS, ER ;
HAYES, WC .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :880-886
[5]  
BROWN G, 1995, AM AC SPORTS MED FIN, P83
[6]  
BUTLER DL, 1987, AAOS INSTR COURSE LE, V36, P173
[7]   OPTIMAL GRAFT FIXATION - THE EFFECT OF GAP SIZE AND SCREW SIZE ON BONE PLUG FIXATION IN ACL RECONSTRUCTION [J].
BUTLER, JC ;
BRANCH, TP ;
HUTTON, WC .
ARTHROSCOPY, 1994, 10 (05) :524-529
[8]  
GONZALEZ D, 1996, 63 ANN M AM AC ORTH
[9]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[10]  
JOHNSON RJ, 1995, ARTHR ASS N AM SPEC, P158