Temporal Healing in Rat Achilles Tendon: Ultrasound Correlations

被引:29
作者
Chamberlain, Connie S. [1 ]
Duenwald-Kuehl, Sarah E. [2 ]
Okotie, Gregory [2 ]
Brounts, Sabrina H. [3 ]
Baer, Geoffrey S. [1 ]
Vanderby, Ray [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Orthoped & Rehabil, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Vet Med Surg Sci, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
Defect healing; Ultrasound echo intensity; Biomechanics; Immunohistochemistry; Periostin; HYPER-ELASTIC MATERIALS; ACOUSTOELASTIC ANALYSIS; MECHANICAL-PROPERTIES; LIGAMENT; TISSUE; DISPLACEMENT; INJURY; WAVES;
D O I
10.1007/s10439-012-0689-y
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
The purpose of this study was to explore whether a new ultrasound-based technique correlates with mechanical and biological metrics that describe the tendon healing. Achilles tendons in 32 rats were unilaterally transected and allowed to heal without repair. At 7, 9, 14, or 29 days post-injury, tendons were collected and examined for healing via ultrasound image analysis, mechanical testing, and immunohistochemistry. Consistent with previous studies, we observe that the healing tendons are mechanically inferior (ultimate stress, ultimate load, and normalized stiffness) and biologically altered (cellular and ECM factors) compared to contralateral controls with an incomplete recovery over healing time. Unique to this study, we report: (1) Echo intensity (defined by gray-scale brightness in the ultrasound image) in the healing tissue is related to stress and normalized stiffness. (2) Elongation to failure is relatively constant so that tissue normalized stiffness is linearly correlated with ultimate stress. Together, 1 and 2 suggest a method to quantify mechanical compromise in healing tendons. (3) The amount and type of collagen in healing tendons associates with their strength and normalized stiffness as well as their ultrasound echo intensity. (4) A significant increase of periostin in the healing tissues suggests an important but unexplored role for this ECM protein in tendon healing.
引用
收藏
页码:477 / 487
页数:11
相关论文
共 24 条
[1]
MECHANICAL BEHAVIOUR OF TENDON IN VITRO - A PRELIMINARY REPORT [J].
ABRAHAMS, M .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (05) :433-+
[2]
Quantification of Collagen Organization and Extracellular Matrix Factors within the Healing Ligament [J].
Chamberlain, Connie S. ;
Crowley, Erin M. ;
Kobayashi, Hirohito ;
Eliceiri, Kevin W. ;
Vanderby, Ray .
MICROSCOPY AND MICROANALYSIS, 2011, 17 (05) :779-787
[3]
Gene profiling of the rat medial collateral ligament during early healing using microarray analysis [J].
Chamberlain, Connie S. ;
Brounts, Sabrina H. ;
Sterken, David G. ;
Rolnick, Kevin I. ;
Baer, Geoffrey S. ;
Vanderby, Ray .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (02) :552-565
[4]
The spatio-temporal dynamics of ligament healing [J].
Chamberlain, Connie S. ;
Crowley, Erin ;
Vanderby, Ray .
WOUND REPAIR AND REGENERATION, 2009, 17 (02) :206-215
[5]
VISCOELASTIC CREEP OF COLLAGENOUS TISSUE [J].
COHEN, RE ;
HOOLEY, CJ ;
MCCRUM, NG .
JOURNAL OF BIOMECHANICS, 1976, 9 (04) :175-184
[6]
Ultrasound echo is related to stress and strain in tendon [J].
Duenwald, Sarah ;
Kobayashi, Hirohito ;
Frisch, Kayt ;
Lakes, Roderic ;
Vanderby, Ray, Jr. .
JOURNAL OF BIOMECHANICS, 2011, 44 (03) :424-429
[7]
Unloaded rat Achilles tendons continue to grow, but lose viscoelasticity [J].
Eliasson, Pernilla ;
Fahlgren, Anna ;
Pasternak, Bjorn ;
Aspenberg, Per .
JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (02) :459-463
[8]
2ND-ORDER ELASTIC DEFORMATION OF SOLIDS [J].
HUGHES, DS ;
KELLY, JL .
PHYSICAL REVIEW, 1953, 92 (05) :1145-1149
[9]
Mechanics of tendon, from an engineering perspective [J].
Ker, Robert F. .
INTERNATIONAL JOURNAL OF FATIGUE, 2007, 29 (06) :1001-1009
[10]
New strain energy function for acoustoelastic analysis of dilatational waves in nearly incompressible, hyper-elastic materials [J].
Kobayashi, H ;
Vanderby, R .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2005, 72 (06) :843-851