Therapeutic isoniazid monitoring using a simple high-performance liquid chromatographic method with ultraviolet detection

被引:41
作者
Moussa, LA
Khassouani, CE
Soulaymani, R
Jana, M
Cassanas, G
Alric, R
Hüe, B
机构
[1] Natl Inst Hyg, Ctr Antipoisons Maroc, Lab Toxicol Urgence & Suivi Therapeut, Rabat 11400, Morocco
[2] Fac Sci Semlalia, Marrakech, Morocco
[3] Fac Pharm Montpellier, Lab Phys Ind, F-34060 Montpellier, France
[4] Fac Med Montpellier, Pharmacol Lab, Montpellier, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 766卷 / 01期
关键词
isoniazid;
D O I
10.1016/S0378-4347(01)00434-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simultaneous measurement of isoniazid and its main acetylated metabolite acetylisoniazid in human plasma is realized by high-performance liquid chromatography. The technique used is evaluated by a factorial design of validation that proved to be convenient for routine drug monitoring. Plasma samples are deproteinized by trichloroacetic acid and then the analytes are separated on a muBondapak C-18 column (Waters). Nicotinamide is used as an internal standard. The mobile phase is 0.05 M ammonium acetate buffer (pH 6)-acetonitrile (99:1, v/v). The detection is by ultraviolet absorbance at 275 nm. The validation, using the factorial design allows one to: (a) test the systematic factors of bias (linearity and matrix effect); (b) estimate the relative standard deviations (RSDs) related to extraction, measure and sessions assay. The linearity is confirmed to be within a range of 0.5 to 8 mug/ml of isoniazid and 1 to 16 mug/ml of acetylisoniazid. This method shows a good repeatability for both extraction and measurement (RSD INH=3.54% and 3.32%; RSD Ac.INH=0.00% and 5.97%), as well as a good intermediate precision (RSD INH=7.96%; RSD Ac.INH=15.86%). The method is also selective in cases of polytherapy as many drugs are associated (rifampicin, ethambutol, pyrazinamide, streptomycin). The matrix effect (plasma vs. water) is negligible for INH (3%), but statistically significant for AC.INH (11%). The application of this validation design gave us the possibility to set up an easy and suitable method for INH therapeutic monitoring. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 33 条
[1]  
ALRIC R, 1984, METHOD FIND EXP CLIN, V6, P353
[2]   Determination of N-acetylation phenotyping in a Greek population using caffeine as a metabolic probe [J].
Asprodini, EK ;
Zifa, E ;
Papageorgiou, I ;
Benakis, A .
EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 1998, 23 (04) :501-506
[3]  
Barhoumi C, 1995, Tunis Med, V73, P379
[4]   CAFFEINE METABOLISM IN A HEALTHY SPANISH POPULATION - N-ACETYLATOR PHENOTYPE AND OXIDATION PATHWAYS [J].
CARRILLO, JA ;
BENITEZ, J .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1994, 55 (03) :293-304
[5]  
Chapuzet E., 1997, STP Pharma Pratiques, V7, P169
[6]   High-performance liquid chromatographic determination of fluconazole in plasma [J].
Cociglio, M ;
Brandissou, S ;
Alric, R ;
Bressolle, F .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :11-17
[7]   DETERMINATION OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE BY LIQUID-CHROMATOGRAPHY FOR ROUTINE MONITORING OF PLASMA-LEVELS [J].
COCIGLIO, M ;
HILLAIREBUYS, D ;
ALRIC, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 674 (01) :101-110
[8]   Prevalidation statistical design to assess analytical methods - Example of a quick liquid chromatographic assay of itraconazole in serum [J].
Cociglio, M ;
HillaireBuys, D ;
Alric, R .
JOURNAL OF CHROMATOGRAPHY B, 1997, 698 (1-2) :225-233
[9]   DETERMINATION OF ACETYLATOR PHENOTYPE USING MATRIX ISONIAZID [J].
ELLARD, GA ;
GAMMON, PT ;
TIITINEN, H .
TUBERCLE, 1975, 56 (03) :203-209
[10]   FACTORS IN HYDRAZINE FORMATION FROM ISONIAZID BY PEDIATRIC AND ADULT TUBERCULOSIS PATIENTS [J].
GENT, WL ;
SEIFART, HI ;
PARKIN, DP ;
DONALD, PR ;
LAMPRECHT, JH .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 43 (02) :131-136