Analysis of bioactive peptides by liquid chromatography high-resolution electrospray mass spectrometry

被引:17
作者
DAgostino, PA
Hancock, JR
Provost, LR
机构
[1] Def. Research Establishment Suffield, Medicine Hat, Alta. T1A 8K6
关键词
molecular mass determination; detection; LC; peptides; bradykinins; substance P;
D O I
10.1016/S0021-9673(97)00017-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
LC-high-resolution electrospray ionization (ESI)-MS data for a number of bioactive peptides, including substance P and bradykinins were acquired over a wide mass range by scanning the magnetic sector and calibrating externally with polyethylene glycol standards. Multiply charged ions were observed and errors between observed and theoretical monoisotopic molecular masses were typically in the 5 to 30 ppm range for the peptides during LC-ESI-MS and ESI-MS operation with magnetic sector resolutions between 2500 and 6000 (10% valley definition). Under collisionally activated dissociation conditions b(n)(-) and y(n)-series sequence ions were generally observed, enabling amino acid sequencing and the differentiation of lysine from glutamine, two amino acids differing in residue mass by only 0.0364 u. Mass accuracy was evaluated during an international round robin analytical exercise where the molecular masses of five unknown peptides were to be accurately determined. Isotopic clusters for charge states of up to +6 were fully resolved, facilitating the rapid and unambiguous assignment of charge states and calculation of monoisotopic molecular masses. Errors between theoretical and observed monoisotopic molecular masses were in the 2 to 18 ppm range for the five unknown peptides.
引用
收藏
页码:77 / 85
页数:9
相关论文
共 16 条
[1]   FAST ATOM BOMBARDMENT OF SOLIDS (FAB) - A NEW ION-SOURCE FOR MASS-SPECTROMETRY [J].
BARBER, M ;
BORDOLI, RS ;
SEDGWICK, RD ;
TYLER, AN .
JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1981, (07) :325-327
[2]   MASS-SPECTROMETRY OF PEPTIDES AND PROTEINS [J].
BIEMANN, K .
ANNUAL REVIEW OF BIOCHEMISTRY, 1992, 61 :977-1010
[3]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF HIGH-MASS BIOMOLECULES [J].
BUCHANAN, MV ;
HETTICH, RL .
ANALYTICAL CHEMISTRY, 1993, 65 (05) :A245-&
[4]  
BURLINGAME AL, 1994, ANAL CHEM, V66, pR634
[5]   ADVANTAGES OF HIGH-RESOLUTION AND HIGH-MASS RANGE MAGNETIC-SECTOR MASS-SPECTROMETRY FOR ELECTROSPRAY IONIZATION [J].
CHAPMAN, JR ;
GALLAGHER, RT ;
BARTON, EC ;
CURTIS, JM ;
DERRICK, PJ .
ORGANIC MASS SPECTROMETRY, 1992, 27 (03) :195-203
[6]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[7]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTROMETRY WITH A MAGNETIC-SECTOR INSTRUMENT - ACCURATE MASS MEASUREMENT AND PEPTIDE SEQUENCING [J].
DAGOSTINO, PA ;
HANCOCK, JR ;
PROVOST, LR ;
SEMCHUK, PD ;
HODGES, RS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (07) :597-603
[8]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[9]   AN ELECTROSPRAY ION-SOURCE FOR MAGNETIC-SECTOR MASS SPECTROMETERS [J].
LARSEN, BS ;
MCEWEN, CN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) :205-211
[10]   PRIMARY TO QUATERNARY PROTEIN-STRUCTURE DETERMINATION WITH ELECTROSPRAY-IONIZATION AND MAGNETIC-SECTOR MASS-SPECTROMETRY [J].
LOO, JA ;
LOO, RRO ;
ANDREWS, PC .
ORGANIC MASS SPECTROMETRY, 1993, 28 (12) :1640-1649