Detection of HCV core antigen in human serum and plasma with an automated chemiluminescent immunoassay

被引:42
作者
Muerhoff, AS
Jiang, L
Shah, DO
Gutierrez, RA
Patel, J
Garolis, C
Kyrk, CR
Leckie, G
Frank, A
Stewart, JL
Dawson, GJ
机构
[1] Abbott Labs, Expt Biol Res, Dept 90D, Abbott Diagnost Div, N Chicago, IL 60064 USA
[2] Abbott Labs, Mol Diagnost Assay Dev, Abbott Diagnost Div, N Chicago, IL 60064 USA
[3] Abbott Labs, PRISM Res & Dev, Abbott Diagnost Div, N Chicago, IL 60064 USA
关键词
D O I
10.1046/j.1537-2995.2002.00052.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Currently, the detection of HCV infection in blood donors relies on the ability of immunoassays to detect circulating HCV antibodies. However, a significant delay exists between the time of infection and the development of antibodies. This delay (window period) can last up to 70 days. The introduction of NAT for the detection of HCV RNA has reduced this window period dramatically. However, NAT is labor Intensive, prone to contamination, and expensive as compared with standard serologic tests. STUDY DESIGN AND METHODS: An automated, microparticle-based chemiluminescent assay for the detection of HCV core antigen in human serum and plasma was developed. The specificity and sensitivity of this prototype assay were evaluated by testing a population of normal blood donors and commercially available seroconversion panels. RESULTS: The HCV core antigen assay exhibited a 99.9-percent specificity by detecting a single repeatably reactive sample out of 1004 normal donors tested. Assay sensitivity was determined by comparing the HCV core antigen detection rate with the antibody seroconversion profile and the rate of HCV RNA detection. Among 15 seroconversion panels examined, core antigen was detected in 69 of 70 antibody-negative and/or RNA-positive samples for a sensitivity relative to NAT of 98.6 percent. CONCLUSION: These data indicate that the automated, microparticle-based chemiluminescent HCV core antigen assay can reduce the window period for detection of potentially infected blood donors by 32.7 days, and it represents a viable alternative to HCV RNA testing.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 30 条
  • [1] Development of a simple and highly sensitive enzyme immunoassay for hepatitis C virus core antigen
    Aoyagi, K
    Ohue, C
    Iida, K
    Kimura, T
    Tanaka, E
    Kiyosawa, K
    Yagi, S
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (06) : 1802 - 1808
  • [2] IMPORTANCE OF PRIMER SELECTION FOR THE DETECTION OF HEPATITIS-C VIRUS-RNA WITH THE POLYMERASE CHAIN-REACTION ASSAY
    BUKH, J
    PURCELL, RH
    MILLER, RH
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (01) : 187 - 191
  • [3] Busch M. P., 2000, Transfusion (Bethesda), V40, P143
  • [4] Declining value of alanine aminotransferase in screening of blood donors to prevent posttransfusion hepatitis B and C virus infection
    Busch, MP
    Korelitz, JJ
    Kleinman, SH
    Lee, SR
    AuBuchon, JP
    Schreiber, GB
    Williams, AE
    Ownby, HE
    Waxman, DA
    Hutching, S
    Murphy, EL
    Gilcher, RO
    Smith, JW
    Thomson, RA
    Nemo, GJ
    Zuck, TF
    [J]. TRANSFUSION, 1995, 35 (11) : 903 - 910
  • [5] Efficacy of HCV core antigen detection during the preseroconversion period
    Couroucé, AM
    Le Marrec, N
    Bouchardeau, F
    Razer, A
    Maniez, M
    Laperche, S
    Simon, N
    [J]. TRANSFUSION, 2000, 40 (10) : 1198 - 1202
  • [6] Dawson GJ, 2000, TRANSFUSION, V40, p83S
  • [7] Quantification of serum HCV core antigen by a fluorescent enzyme immunoassay in liver transplant recipients with recurrent hepatitis C - Clinical and virologic implications
    Dickson, RC
    Mizokami, M
    Orito, E
    Qian, KP
    Lau, JYN
    [J]. TRANSPLANTATION, 1999, 68 (10) : 1512 - 1516
  • [8] FELSENSTEIN J, 1993, PHYLIP INFERENCE PAC
  • [9] Hottentrager B, 2001, J HEPATOL, V34, P128
  • [10] HOTTENTRAGER B, 2001, HEPATOLOGY, V34, pA1327