The dynamic relationship between end-tidal sevoflurane and isoflurane concentrations and bispectral index and spectral edge frequency of the electroencephalogram

被引:139
作者
Olofsen, E [1 ]
Dahan, A [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Anesthesiol, NL-2300 RC Leiden, Netherlands
关键词
cross-validation; pharmacodynamic modeling; volatile anesthetics;
D O I
10.1097/00000542-199905000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Inhalational anesthetics produce dose-dependent effects on electroencephalogram-derived parameters, such as 95% spectral edge frequency (SEF) and bispectral index (BIS), The authors analyzed the relationship between end-tidal sevoflurane and isoflurane concentrations (FET) and BIS and SEF and determined the speed of onset and offset of effect (t(1/2)k(e0)). Methods: Twenty-four patients with American Society of Anesthesiologists physical status I or II were randomly assigned to receive anesthesia with sevoflurane or isoflurane. Several transitions between 0.5 and 1.5 minimum alveolar concentration mere performed. BIS and SEF data were analyzed with a combination of an effect compartment and an inhibitory sigmoid E-max model, characterized by t(1/2)k(e0), the concentration at which 50% depression of the electroencephalogram parameters occurred (IC50), and shape parameters. Parameter values estimated are mean +/- SD. Results: The model adequately described the FET-BIS relationship. Values for t(1/2)k(e0), derived from the BIS data, mere 3.5 +/- 2.0 and 3.2 +/- 0.7 min for sevoflurane and isoflurane, respectively (NS). Equivalent values derived from SEF mere 3.1 +/- 2.4 min (sevoflurane) and 2.3 +/- 1.2 min (isoflurane; NS). Values of t(1/2)k(e0) derived from the SEF were smaller than those from BIS (P < 0.05). IC50 values derived from the BIS were 1.14 +/- 0.31% (sevoflurane) and 0.60 +/- 0.11% (isoflurane; P < 0.05), Conclusions: The speed of onset and offset of anesthetic effect did not differ between isoflurane and sevoflurane; isoflurane was approximately twice as potent as sevoflurane. The greater values of t(1/2)k(e0), derived from the BIS data compared with those derived from the SEF data may be related to computational and physiologic delays.
引用
收藏
页码:1345 / 1353
页数:9
相关论文
共 28 条
[11]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[12]   Electroencephalographic derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane [J].
Katoh, T ;
Suzuki, A ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (03) :642-650
[13]  
KATOH T, 1993, ANESTH ANALG, V77, P1012
[14]   Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis [J].
Kearse, LA ;
Rosow, C ;
Zaslavsky, A ;
Connors, P ;
Dershwitz, M ;
Denman, W .
ANESTHESIOLOGY, 1998, 88 (01) :25-34
[15]   Blood flow velocity of middle cerebral artery during prolonged anesthesia with halothane, isoflurane, and sevoflurane in humans [J].
Kuroda, Y ;
Murakami, M ;
Tsuruta, J ;
Murakawa, T ;
Sakabe, T .
ANESTHESIOLOGY, 1997, 87 (03) :527-532
[16]  
Mapleson WW, 1996, BRIT J ANAESTH, V76, P179, DOI 10.1093/bja/76.2.179
[17]   VARIATION IN LOCAL CEREBRAL BLOOD-FLOW RESPONSE TO HIGH-DOSE PENTOBARBITAL SODIUM IN THE RAT [J].
OTSUKA, T ;
WEI, L ;
ACUFF, VR ;
SHIMIZU, A ;
PETTIGREW, KD ;
PATLAK, CS ;
FENSTERMACHER, JD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1991, 261 (01) :H110-H120
[18]   ANESTHETIC POTENCY (MAC) IS INDEPENDENT OF FOREBRAIN STRUCTURES IN THE RAT [J].
RAMPIL, IJ ;
MASON, P ;
SINGH, H .
ANESTHESIOLOGY, 1993, 78 (04) :707-712
[19]   A primer for EEG signal processing in anesthesia [J].
Rampil, IJ .
ANESTHESIOLOGY, 1998, 89 (04) :980-1002
[20]  
ROSOW C, 1998, ANESTHESIOL CLIN N A, V2, P89