Advances in utrasound

被引:124
作者
Harvey, CJ
Pilcher, JM
Eckersley, RJ
Blomley, MJK
Cosgrove, DO
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Sch Med, Dept Imaging, London W12 0NN, England
[2] St George Hosp, Dept Imaging, London, England
关键词
ultrasonography; ultrasound technology; non-linear ultrasound imaging; ultrasound contrast agents; review;
D O I
10.1053/crad.2001.0918
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ultrasound (US) has undergone dramatic changes since its inception three decades ago; the original cumbersome B-mode gantry system has evolved into a high resolution real-time imaging system. This review describes both recent advances in ultrasound and contrast media and likely future developments. Technological advances in electronics and computing have revolutionized ultrasound practice with ever expanding applications. Developments in transducer materials and array designs have resulted in greater bandwidths with improvements in spatial and contrast resolution. Developments in digital signal processing have produced innovations in beam forming, image display and archiving. Technological advances have resulted in novel imaging modes which exploit the non-linear behaviour of tissue and microbubble contrast agents. Microbubble contrast agents have dramatically extended the clinical and research applications of ultrasound. Not only can Doppler studies be enhanced but also novel non-linear modes allow vessels down to the level of the microcirculation to be imaged. Functional and quantitative studies allow interrogation of a wide spectrum of tissue beds. The advent of tissue-specific agents promises to improve the sensitivity and specificity of ultrasound in the detection and characterization of focal liver lesions to rival that of computed tomography (CT) and magnetic resonance imaging (MRI). Ultrasound has recently moved into therapeutic applications with high intensity focused ultrasound (HIFU) and microbubble assisted delivery of drugs and genes showing great promise. (C) 2002 The Royal College of Radiologists.
引用
收藏
页码:157 / 177
页数:21
相关论文
共 78 条
[1]   Enhancement of power Doppler signals from breast lesions with the ultrasound contrast agent EchoGen emulsion: Subjective and quantitative assessment [J].
Albrecht, T ;
Patel, N ;
Cosgrove, DO ;
Jayaram, V ;
Blomley, MJK ;
Eckersley, R .
ACADEMIC RADIOLOGY, 1998, 5 :S195-S198
[2]   Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
LANCET, 1999, 353 (9164) :1579-1583
[3]   Phase-inversion sonography during the liver-specific late phase of contrast enhancement: Improved detection of liver metastases [J].
Albrecht, T ;
Hoffmann, CW ;
Schmitz, SA ;
Schettler, S ;
Overberg, A ;
Germer, CT ;
Wolf, KJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1191-1198
[4]  
ALBRECHT T, 1999, TRENDS CONTRAST MEDI, P367
[5]   Hysterosalpingo-contrast sonography (HyCoSy) using Echovist(R)-200 in the outpatient investigation of infertility patients [J].
Ayida, G ;
Harris, P ;
Kennedy, S ;
Seif, M ;
Barlow, D ;
Chamberlain, P .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (826) :910-913
[6]   Ultrasound elasticity imaging: definition and technology [J].
Bamber, JC .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S327-S330
[7]   Extended field-of-view sonography in musculoskeletal disorders [J].
Barberie, JE ;
Wong, AD ;
Cooperberg, PL ;
Carson, BW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :751-757
[8]   Stimulated acoustic emission in liver parenchyma with Levovist [J].
Blomley, M ;
Albrecht, T ;
Cosgrove, D ;
Jayaram, V ;
Butler-Barnes, J ;
Eckersley, R .
LANCET, 1998, 351 (9102) :568-568
[9]  
Blomley MJ, 1999, RADIOLOGY, V213P, P491
[10]  
Blomley MJ, 2001, RADIOLOGY, V221, P268