Development of a sensitive micro-magnetic chemiluminescence enzyme immunoassay for the determination of carcinoembryonic antigen

被引:74
作者
Dungchai, Wijitar
Siangproh, Weena
Lin, Jin-Ming [1 ]
Chailapakul, Orawon
Lin, Si
Ying, Xitang
机构
[1] Tsing Hua Univ, Dept Chem, Minist Educ, Key Lab Bioorgan Phosphorus Chem & Chem Biol, Beijing 100084, Peoples R China
[2] Chulalongkorn Univ, Fac Sci, Dept Chem, Bangkok 10330, Thailand
[3] Beijing Acad Sci & Technol, Beijing Chemclin Biotech Co Ltd, Beijing 100094, Peoples R China
关键词
micro-magnetic beads; carcinoembryonic antigen; tumor; chemiluminescence enzyme immunoassay; marker;
D O I
10.1007/s00216-006-0899-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A micro-magnetic chemiluminescence (CL) enzyme immunoassay with high sensitivity, selectivity, and reproducibility was developed for the determination of the tumor marker, carcinoembryonic antigen (CEA) in human serum. A sandwich scheme assay has been utilized with fluorescein isothiocyanate antibody (FITC)-labeled anti-CEA antibody and alkaline phosphate (ALP)-labeled anti-CEA antibody being used in the CL detection. The CL signal produced by the emission of photons from 4-methoxy-4-(3-phosphate-phenyl)-spiro-(1,2-dioxetane-3,2'-adamantane) (AMPPD) was directly proportional to the amount of analyte present in a sample solution. The influences of the reaction time of antigen with antibody, the reaction time of substrate with label, the dilution ratio of ALP-labeled anti-CEA antibody, the concentration of FITC-labeled anti-CEA antibody, and other relevant variables upon the CL signal were examined and optimized. The CL responses depended linearly on the CEA concentration over the range from 2 to 162 ng mL(-1) in a logarithmic plot. Assay sensitivity as low as 0.69 ng mL(-1) was achieved. A coefficient of variance of less than 13% was obtained for intra- and inter-assay precision. This method has been successfully applied to the analysis of CEA in human serum. According to the procedure based on spiked standards, the recoveries obtained were 80-110%. Comparison experiments were carried out with the commercially available CEA chemiluminescence immunoassay. Satisfactory results were obtained according to a paired t-test method (t value < t(critical) at the 95% confidence level).
引用
收藏
页码:1965 / 1971
页数:7
相关论文
共 34 条
  • [1] ALMAN DG, 1983, STATISTICIAN, V32, P307
  • [2] [Anonymous], 1952, Methods of Statistical Analysis
  • [3] Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine
    Biagini, RE
    Smith, JP
    Sammons, DL
    MacKenzie, BA
    Striley, CAF
    Robertson, SK
    Snawder, JE
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) : 368 - 374
  • [4] *BIOCH INMC, BC1011 BIOCH INC
  • [5] Cheli CD, 1999, J CLIN LAB ANAL, V13, P35, DOI 10.1002/(SICI)1098-2825(1999)13:1<35::AID-JCLA7>3.3.CO
  • [6] 2-I
  • [7] CHU TM, 1979, CARCINOEMBRYONIC PRO, V1, P55
  • [8] DELWICHE R, 1973, CANCER, V31, P328, DOI 10.1002/1097-0142(197302)31:2<328::AID-CNCR2820310209>3.0.CO
  • [9] 2-J
  • [10] A colorimetric immunoassay for the detection of E-cadherin and calcinoembryonic antigen (CEA) expression on human colon carcinoma cell lines in vitro
    Eckert, K
    FuhrmannSelter, T
    Maurer, HR
    Buttner, P
    [J]. CANCER LETTERS, 1996, 105 (01) : 1 - 4