Development of a sensitivity enhanced multiplexed fluorescence covalent microbead immunosorbent assay (FCMIA) for the measurement of glyphosate, atrazine and metolachlor mercapturate in water and urine

被引:33
作者
Biagini, RE [1 ]
Smith, JP [1 ]
Sammons, DL [1 ]
MacKenzie, BA [1 ]
Striley, CAF [1 ]
Robertson, SK [1 ]
Snawder, JE [1 ]
机构
[1] NIOSH, Biomonitoring & Hlth Assessment Branch, Div Appl Res & Technol, Ctr Dis Control & Prevent, Cincinnati, OH 45226 USA
关键词
biomonitoring; luminex; glyphosate; atrazine; metolachlor mercapturate;
D O I
10.1007/s00216-004-2628-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Body burdens from exposures to pesticides may be estimated from urinary analyses of pesticide parent/metabolite concentrations. Pesticide applicators and others are often exposed to numerous unrelated pesticides, either sequentially or simultaneously. Classically, body burdens of pesticides are analyzed using chemical/instrumental analysis (CIM) or enzyme immunoassays (EIAs). Both of these technologies can usually be used to quantitate one analyte (or closely related groups of analytes) per analysis. Alternatively, multiple analytes can be measured simultaneously using a multiplexed fluorescence covalent microbead immunoassay (FCMIA). We developed a multiplexed FCMIA to simultaneously measure glyphosate (Gly), atrazine (Atz), and metolachlor mercapturate (MM) in water and urine. The assay had least detectable doses (LDDs) in water/diluted urine of 0.11/0.09 ng/ml (Gly, water/urine LDD), 0.10/0.07 ng/ml (Atz), and 0.09/0.03 ng/ml (MM). The sensitivity for the measurement of Gly was enhanced by derivatization. All assays gave linear responses from the LDDs for each respective pesticide to 300 ng/ml. There was no cross-reactivity between the three analytes. Using a 96-well microplate and an autosampler, as many as 288 separate analyses can be completed in similar to120 min with precision, sensitivity, and specificity equivalent to, if not better, than that found when these same analytes are measured by CIM or EIA.
引用
收藏
页码:368 / 374
页数:7
相关论文
共 29 条
  • [1] Ashton F.M., 1991, Weed Science - Principles and Practices, V3rd
  • [2] Quantification of selected pesticide metabolites in human urine using isotope dilution high-performance liquid chromatography/tandem mass spectrometry
    Baker, SE
    Barr, DB
    Driskell, WJ
    Beeson, MD
    Needham, LL
    [J]. JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2000, 10 (06): : 789 - 798
  • [3] A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry
    Barr, DB
    Barr, JR
    Maggio, VL
    Whitehead, RD
    Sadowski, MA
    Whyatt, RM
    Needham, LL
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 99 - 111
  • [4] Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins
    Biagini, RE
    Sammons, DL
    Smith, JP
    MacKenzie, BA
    Striley, CAF
    Semenova, V
    Steward-Clark, E
    Stamey, K
    Freeman, AE
    Quinn, CP
    Snawder, JE
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (01) : 50 - 55
  • [5] BIAGINI RE, 1995, B ENVIRON CONTAM TOX, V54, P245
  • [6] Method for simultaneous measurement of antibodies to 23 pneumococcal capsular polysaccharides
    Biagini, RE
    Schlottmann, SA
    Sammons, DL
    Smith, JP
    Snawder, JC
    Striley, CAF
    MacKenzie, BA
    Weissman, DN
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (05) : 744 - 750
  • [7] Development of multiplexed fluorescence microbead covalent assays (FMCAs) for pesticide biomonitoring
    Biagini, RE
    Murphy, DM
    Sammons, DL
    Smith, JP
    Striley, CAF
    MacKenzie, BA
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2002, 68 (04) : 470 - 477
  • [8] Blondell J, 1997, OCCUP MED, V12, P209
  • [9] Glyphosate applied preharvest induces shikimic acid accumulation in hard red spring wheat (Triticum aestivum)
    Bresnahan, GA
    Manthey, FA
    Howatt, KA
    Chakraborty, M
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (14) : 4004 - 4007
  • [10] Determination of herbicides, including thermally labile phenylureas, by solid-phase microextraction and gas chromatography-mass spectrometry
    Carabias-Martínez, R
    García-Hermida, C
    Rodríguez-Gonzalo, E
    Soriano-Bravo, FE
    Hernández-Méndez, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) : 1 - 12