Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models

被引:130
作者
Leung, James H. [1 ]
Wright, Andrew R.
Cheshire, Nick
Crane, Jeremy
Thom, Simon A.
Hughes, Alun D.
Xu, Yun
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem Engn, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Int Ctr Circulatory Hlth, Natl Heart & Lung Inst, London, England
关键词
D O I
10.1186/1475-925X-5-33
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Abdominal aortic aneurysm (AAA) is a dilatation of the aortic wall, which can rupture, if left untreated. Previous work has shown that, maximum diameter is not a reliable determinant of AAA rupture. However, it is currently the most widely accepted indicator. Wall stress may be a better indicator and promising patient specific results from structural models using static pressure, have been published. Since flow and pressure inside AAA are non-uniform, the dynamic interaction between the pulsatile flow and wall may influence the predicted wall stress. The purpose of the present study was to compare static and dynamic wall stress analysis of patient specific AAAs. Method: Patient-specific AAA models were created from CT scans of three patients. Two simulations were performed on each lumen model, fluid structure interaction (FSI) model and static structural (SS) model. The AAA wall was created by dilating the lumen with a uniform 1.5 mm thickness, and was modeled as a non-linear hyperelastic material. Commercial finite element code Adina 8.2 was used for all simulations. The results were compared between the FSI and SS simulations. Results: Results are presented for the wall stress patterns, wall shear stress patterns, pressure, and velocity fields within the lumen. It is demonstrated that including fluid flow can change local wall stresses slightly. However, as far as the peak wall stress is concerned, this effect is negligible as the difference between SS and FSI models is less than 1%. Conclusion: The results suggest that fully coupled FSI simulation, which requires considerable computational power to run, adds little to rupture risk prediction. This justifies the use of SS models in previous studies.
引用
收藏
页数:15
相关论文
共 53 条
[21]   Fluid-structure interaction effects on sac-blood pressure and wall stress in a stented aneurysm [J].
Li, Z ;
Kleinstreuer, C .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04) :662-671
[22]  
LI Z, IN PRESS J BIOMECHAN
[23]   Blood flow and structure interactions in a stented abdominal aortic aneurysm model [J].
Li, ZH ;
Kleinstreuer, C .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) :369-382
[24]  
Long Q, 2000, MAGN RESON MED, V43, P565, DOI 10.1002/(SICI)1522-2594(200004)43:4<565::AID-MRM11>3.0.CO
[25]  
2-L
[26]  
Marra S, 2005, P 2005 SUMM BIOENG C
[27]  
Moore JA, 1998, J BIOMECH, V31, P179, DOI 10.1016/S0021-9290(97)00125-5
[28]   PULSATILE VELOCITY-MEASUREMENTS IN A MODEL OF THE HUMAN ABDOMINAL-AORTA UNDER RESTING CONDITIONS [J].
MOORE, JE ;
KU, DN .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1994, 116 (03) :337-346
[29]   Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions [J].
Olufsen, MS ;
Peskin, CS ;
Kim, WY ;
Pedersen, EM ;
Nadim, A ;
Larsen, J .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (11) :1281-1299
[30]  
OUTTEN JT, 2003, P 2003 SUMM BIOENG C